The remote distractor effect (RDE) is a well-known and robust phenomenon whereby latencies of saccades are increased when a distractor is presented simultaneously along with the saccade target. Studies of the RDE in patients with a loss of vision in one visual field (hemianopia) following damage to primary visual cortex have provided conflicting results. Rafal, Smith, Krantz, Cohen, and Brennan (1990) reported a naso-temporal asymmetry in the RDE in patients with hemianopias, with a greater influence of distractors presented in their blind temporal visual field. This asymmetry was not observed in typically sighted controls. By contrast, Walker, Mannan, Maurer, Pambakian, and Kennard (2000) observed no effect of distractors presented to either the blind nasal or blind temporal hemifield of hemianopes, but the naso-temporal asymmetry was observed in typically sighted controls. The present study addressed one potential methodological differences between the two studies by investigating the inhibitory effect of a distractor on saccade latency in neurotypical participants. Here participants were tested monocularly and the effect of a nasal/temporal hemifield distractor on saccade latency observed in the presence or absence of peripheral placeholders. Our results showed a naso-temporal asymmetry in the magnitude of the RDE in the no placeholder condition, with a greater RDE when the distractor was presented in the temporal visual field. However, in the placeholder condition the opposite asymmetry was observed, that is an increased RDE when the distractor was presented in the nasal visual field. Our results suggest that the presence/absence of a placeholder might be the critical factor explaining the discrepancy between Rafal et al. (1990) and Walker et al. (2000) in participants without visual field loss. The current results can be interpreted in terms of additional inhibitory or attentional processes that bias selection towards stimuli in the nasal hemifield in the presence of placeholders, still, the mechanisms underlying these effects remain unclear.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cortex.2021.04.007DOI Listing

Publication Analysis

Top Keywords

visual field
20
naso-temporal asymmetry
16
distractor presented
12
asymmetry observed
12
presence placeholders
8
remote distractor
8
rde patients
8
distractors presented
8
presented blind
8
blind temporal
8

Similar Publications

Global Publication Trends and Research Hotspots of Diabetes and Osteoporosis.

Endocr Metab Immune Disord Drug Targets

January 2025

Department of Rheumatology and Immunology, The First Affiliated Hospital of Army Medical University, Chongqing, China.

Background: Diabetes and osteoporosis, as chronic diseases with high incidence, have caused deep concern in the field of global public health due to their high morbidity and mortality. More importantly, the complex and close relationship between diabetes and osteoporosis has gradually become the focus of scientific research. It is very meaningful to carry out bibliometric analysis in the research field of diabetes and osteoporosis to describe the current international trend and present a visual representation of the past and emerging trends of diabetes and osteoporosis in the past decade.

View Article and Find Full Text PDF

Background: Diabetes has a substantial impact on public health, highlighting the need for novel treatments. Ubiquitination, an intracellular protein modification process, is emerging as a promising strategy for regulating pathological mechanisms. We hypothesize that ubiquitination plays a critical role in the development and progression of diabetes and its complications, and that understanding these mechanisms can lead to new therapeutic approaches.

View Article and Find Full Text PDF

Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures.

View Article and Find Full Text PDF

This study analyzes the self-mention forms represented by first-person pronouns (I, me, my, we, us, and our), self-citations, and other forms of mentions made by the same author(s) in each article (e.g., this writer, the author, the authors, the research team) in a corpus of academic articles (625,195 words) in Design area disciplines to determine the similarities and differences in self-mention practices within these disciplines and the previous findings reported in the literature of authorial self-representation observed in hard and soft fields.

View Article and Find Full Text PDF

Widespread screening is crucial for the early diagnosis and treatment of glaucoma, the leading cause of visual impairment and blindness. The development of portable technologies, such as smartphone-based ophthalmoscopes, able to image the optical nerve head, represents a resource for large-scale glaucoma screening. Indeed, they consist of an optical device attached to a common smartphone, making the overall device cheap and easy to use.

View Article and Find Full Text PDF