The exogenous anabolic-androgenic steroid (AAS) stanozolol stays one of the most detected substances in professional sports. Its detection is a fundamental part of doping analysis, and the analysis of this steroid has been intensively investigated for a long time. This contribution to the detection of stanozolol doping describes for the first time the unambiguous proof for the existence of 17-epistanozolol-1'N-glucuronide and 17-epistanozolol-2'N-glucuronide in stanozolol-positive human urine samples due to the access to high-quality reference standards. Examination of excretion study samples shows large detection windows for the phase-II metabolites stanozolol-1'N-glucuronide and 17-epistanozolol-1'N-glucuronide up to 12 days and respectively up to almost 28 days. In addition, we present appropriate validation parameters for the analysis of these metabolites using a fully automatic method online solid-phase extraction (SPE) method already published before. Limits of identification (LOIs) as low as 100 pg/ml and other validation parameters like accuracy, precision, sensitivity, robustness, and linearity are given.