Introduction: To avoid the DRUJ surgical procedures disadvantages, a new intraosseous distal radioulnar prosthesis designed on Sauvé-Kapandji procedure has been introduced. Stability of the prosthesis and biomechanics are to be evaluated in this article.
Materials And Methods: On a cadaveric study, during placement of the prosthesis, biometry of the bones, prosthesis stability (in axial and lateral tractions, wrist pronation and supination, and squeeze test), wrist range of motion before and after implantation, and radiographic evaluation were done on 16 cadavers.
Results: Range of motion of the wrist joint before and after the insertion of the prosthesis, had no significant difference in all six directions. Stability of the prosthesis, when rotational pronation force was exerted, was greater than when rotational supination force was exerted. The prosthesis showed significant stability against longitudinal traction forces in a way that no prosthesis dislocation was observed up to 150N forces. Stability of the prosthesis was investigated when lateral force was applied to different wrist positions. The most stable position of the prosthesis was in the case of lateral traction forces in supination where no case of dislocation was observed.
Conclusions: The intraosseous distal radioulnar prosthesis demonstrated stable structure with no effect on wrist range of motion.
Level Of Evidence: IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2021.102975 | DOI Listing |
J Voice
January 2025
ENT Department, Valencia University General Hospital, Valencia, Spain; Medicine School of Valencia, University of Valencia, Valencia, Spain.
Objetives: Montgomery medialization thyroplasty involves fitting a silicone prosthesis in the thyroid cartilage according to gender-based placement criteria. This standardized procedure can lead in some cases to suboptimal results. The aim of this study is to identify individual anatomical differences between same-gender patients that could explain the occasional failures.
View Article and Find Full Text PDFJ Hand Ther
January 2025
Research Service, James Haley VA, Tampa, FL, USA.
Background: The Activities Measure for Upper Limb Amputation (AM-ULA), an activity measure for prosthesis users, uses a complex grading rubric to assign a single score to task performance which may limit responsiveness.
Purpose: To enhance AM-ULA responsiveness by exploring a scoring that uses multiple grading elements.
Study Design: Cross-sectional study.
Hand Surg Rehabil
January 2025
Università Cattolica del Sacro Cuore, Rome, Italy; UOC Ortopedia e Traumatologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
J Prosthodont
January 2025
Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
Purpose: This study aims to evaluate the effectiveness of a case-based reasoning (CBR) system in predicting the design of definitive obturator prostheses for maxillectomy patients.
Materials And Methods: Data from 209 maxillectomy cases, including extraoral images of obturator prostheses and occlusal images of maxillectomy defects, were collected from Institute of Science Tokyo Hospital. These cases were organized into a structured database using Python's pandas library.
Int Orthop
January 2025
MSk Lab, Imperial College London, London, W12 0BZ, UK.
Purpose: Trauma and orthopaedic (T&O) surgery relies on medical implants and materials, often resulting in metalwork wastage (prosthesis, screws, nails, and plates). This places an economic strain on healthcare services and the environment. Our primary outcome is to quantify the implant wastage across the literature, and secondarily investigate the associated costs in this specialty.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!