Aims: This study aimed to identify any microscopic features associated with abnormal (membranous/velamentous or marginal) placental cord insertions and to analyse their adverse neonatal outcomes.
Methods: We retrospectively analysed the records-including pathological findings, clinical information and pregnancy outcomes-for 1060 singleton pregnancies, involving newborn delivered after 24 weeks of gestation.
Results: Marginal cord insertions were identified in 26.60% of cases and membranous cord insertions in 2.64%. Subchorionic vessel thrombus was more prevalent in marginal or membranous insertions (0.97%) than in normal cord insertions (0.27%) (p=0.129). Intervillous thrombi (13.73% vs 8.41%, p<0.05) and chorioamnionitis (8.53% vs 5.48%, p=0.089) were more prevalent in normal cord insertions. Premature rupture of membranes was significantly more commonly associated with abnormal (marginal 15.25% and membranous 17.86%) than with normal (9.87%) insertions (p<0.05). Pre-eclampsia was more common in the group with membranous cord insertions (7.14%) than in the other groups (marginal 0.35%; normal 0.80%) (p<0.05). Marginal and membranous placental cord insertions were associated with earlier gestational age at delivery and smaller fetuses than in the group with normal insertions. Intrauterine fetal demise, cardiac malformations and pregestational diabetes were also more common among cases of abnormal cord insertions.
Conclusions: Subchorionic vessel thrombus and adverse pregnancy-related outcomes were more prevalent in cases of marginal/membranous cord insertion than for normal insertions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/jclinpath-2020-207342 | DOI Listing |
J Ultrasound Med
January 2025
Department of Obstetrics and Gynecology and Reproductive Sciences, McGovern Medical School, University of Texas, Health Science Center at Houston (UTHealth), Houston, Texas, USA.
Despite its critical importance, the placenta receives substantially less attention during obstetric ultrasound examinations compared to the fetus. The evaluation of the placenta is typically limited to determining its location within the uterus, particularly its relationship to the cervix. Abnormal placenta findings are the result of gross anomalies identified by chance during obstetric examinations, rather than from a systematic evaluation.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Surgical Performance Enhancement and Robotics (SuPER) Centre, Department of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.
The epidural injection is a medical intervention to inject therapeutics directly into the vicinity of the spinal cord for pain management. Because of its proximity to the spinal cord, imprecise insertion of the needle may result in irreversible damage to the nerves or spinal cord. This study explores enhancing procedural accuracy by integrating a telerobotic system and augmented reality (AR) assistance.
View Article and Find Full Text PDFAm J Obstet Gynecol MFM
January 2025
Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, The Netherlands.
Background: Monochorionic (MC) twins share a single placenta which can be unequally shared, leading to selective fetal growth restriction (sFGR). Limited data is available on the prevalence and clinical consequences of proximate cord insertion (PCI) in sFGR pregnancies.
Objective: We aimed to investigate the prevalence of PCI in MC placentas with and without sFGR and per type of sFGR, and study the placental characteristics and perinatal outcome of PCI in sFGR pregnancies.
J Neurotrauma
January 2025
International Collaboration on Repair Discoveries (ICORD), University of British Columbia (UBC), Vancouver, Canada.
Recent studies have reported that monitoring spinal cord perfusion pressure (SCPP) using a pressure probe to measure "intraspinal pressure" (ISP) within the subdural space at the injury site may improve the hemodynamic management of acute spinal cord injury (SCI) patients. This study aimed to investigate, within a pig model of SCI, the relationship between the ISP measured within the subdural space and the "spinal cord pressure" (SCP) measured within the spinal cord itself. Specifically, we sought to characterize the changes to ISP and SCP over time, both rostral and caudal to the injury epicenter, and in relation to native spinal cord morphometry.
View Article and Find Full Text PDFAustralas J Ultrasound Med
November 2024
Discipline of Medical Radiation Science, Curtin Medical School Curtin University Perth Western Australia 6845 Australia.
Introduction/purpose: It is well-documented in the literature that the placenta migrates during pregnancy; however, studies regarding placental cord insertion (PCI) migration are scarce. This longitudinal, prospective study aimed to determine whether PCI migration is a true phenomenon, to assess whether the PCI can change classification during pregnancy and to determine the validity of PCI site documentation including follow-up of abnormal PCI.
Methods: Eighty-three participants who had first, second and third trimester ultrasound examinations at a Western Australian private imaging practice over a 12-month period between November 2021 and November 2022 were recruited.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!