Background: To develop a novel subjective-objective-combined (SOC) grading standard for auto-segmentation for each organ at risk (OAR) in the thorax.

Methods: A radiation oncologist manually delineated 13 thoracic OARs from computed tomography (CT) images of 40 patients. OAR auto-segmentation accuracy was graded by five geometric objective indexes, including the Dice similarity coefficient (DSC), the difference of the Euclidean distance between centers of mass (ΔCMD), the difference of volume (ΔV), maximum Hausdorff distance (MHD), and average Hausdorff distance (AHD). The grading results were compared with those of the corresponding geometric indexes obtained by geometric objective methods in the other two centers. OAR auto-segmentation accuracy was also graded by our subjective evaluation standard. These grading results were compared with those of DSC. Based on the subjective evaluation standard and the five geometric indexes, the correspondence between the subjective evaluation level and the geometric index range was established for each OAR.

Results: For ΔCMD, ΔV, and MHD, the grading results of the geometric objective evaluation methods at our center and the other two centers were inconsistent. For DSC and AHD, the grading results of three centers were consistent. Seven OARs' grading results in the subjective evaluation standard were inconsistent with those of DSC. Six OARs' grading results in the subjective evaluation standard were consistent with those of DSC. Finally, we proposed a new evaluation method that combined the subjective evaluation level of those OARs with the range of corresponding DSC to determine the grading standard. If the DSC ranges between the adjacent levels did not overlap, the DSC range was used as the grading standard. Otherwise, the mean value of DSC was used as the grading standard.

Conclusions: A novel OAR-specific SOC grading standard in thorax was developed. The SOC grading standard provides a possible alternative for evaluation of the auto-segmentation accuracy for thoracic OARs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8173789PMC
http://dx.doi.org/10.1186/s12938-021-00890-8DOI Listing

Publication Analysis

Top Keywords

grading standard
28
subjective evaluation
24
evaluation standard
16
grading
14
soc grading
12
auto-segmentation accuracy
12
geometric objective
12
standard
11
dsc
9
evaluation
9

Similar Publications

Background: Endoscopic submucosal dissection (ESD) is a standardized procedure for intramucosal and slightly invasive submucosal colorectal cancers (CRC). However, the role of ESD for T1b (depth of submucosal invasion: ≥1,000 μm) CRC remains unclear. This study aimed to investigate the long-term efficacy and safety of ESD for T1b CRC.

View Article and Find Full Text PDF

Establishing a living biobank of pediatric high-grade glioma and ependymoma suitable for cancer pharmacology.

Neuro Oncol

January 2025

Childhood Cancer & Cell Death team (C3 team), Consortium South-ROCK, LabEx DEVweCAN, Institut Convergence Plascan, Centre Léon Bérard, Centre de Recherche en Cancérologie de Lyon (CRCL), Université Claude Bernard Lyon 1, INSERM 1052, CNRS 5286, 69008 Lyon, France.

Background: Brain tumors are the deadliest solid tumors in children and adolescents. Most of these tumors are glial in origin and exhibit strong heterogeneity, hampering the development of effective therapeutic strategies. In the past decades, patient-derived tumor organoids (PDT-O) have emerged as powerful tools for modeling tumoral cell diversity and dynamics, and they could then help defining new therapeutic options for pediatric brain tumors.

View Article and Find Full Text PDF

Background: Aging is associated with sustained low-grade inflammation, which has been linked to age-related diseases and mortality. Long-term exercise programs have been shown to be effective to for attenuating this process; however, subsequent detraining might negate some of these benefits. Master athletes, as a model of lifelong consistent exercise practice, have been suggested to present similar inflammatory profiles to untrained young adults.

View Article and Find Full Text PDF

Purpose: Our objective was to identify the dosimetric parameters and prostate volume that most accurately predict the incidence of acute and late gastrointestinal (GI) and genitourinary (GU) toxicity in prostate cancer stereotactic ablative radiotherapy (SABR) treatments.

Methods: We conducted a retrospective analysis of 122 patients who received SABR for prostate cancer at our clinic between March 2018 and September 2022 using a five-fraction SABR regimen. The existing plans of these patients were re-evaluated according to our institutional protocols (Hacettepe University [HU-1] and HU-2) as well as PACE‑B, RTOG 0938, and NRG GU005 dose-volume constraints.

View Article and Find Full Text PDF

Automated classification of coronary LEsions fRom coronary computed Tomography angiography scans with an updated deep learning model: ALERT study.

Eur Radiol

January 2025

Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands.

Objectives: The use of deep learning models for quantitative measurements on coronary computed tomography angiography (CCTA) may reduce inter-reader variability and increase efficiency in clinical reporting. This study aimed to investigate the diagnostic performance of a recently updated deep learning model (CorEx-2.0) for quantifying coronary stenosis, compared separately with two expert CCTA readers as references.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!