Background: The arrhythmic burden after discharge in patients with new-onset left bundle branch block (LBBB) undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 (S3) valve remains largely unknown.

Objective: The purpose of this study was to determine the incidence of late arrhythmias in patients with new-onset LBBB undergoing TAVR with the balloon-expandable S3 valve.

Methods: This was a multicenter, prospective study that included 104 consecutive TAVR patients with new-onset persistent LBBB following TAVR with the S3 valve. An implantable cardiac monitor (Reveal XT, Reveal LINQ) was implanted before discharge. The primary endpoint was the incidence of high-degree atrioventricular block or complete heart block (HAVB/CHB).

Results: A total of 40 patients (38.5%) had at least 1 significant arrhythmic event, leading to a treatment change in 17 (42.5%). Significant bradyarrhythmias occurred in 20 of 104 patients (19.2%) (34 HAVB/CHB episodes, 252 severe bradycardia episodes), with 10 of 20 patients (50%) exhibiting at least 1 episode of HAVB/CHB. Most HAVB/CHB episodes (60%) occurred within 4 weeks after discharge. Nine patients (8.7%) underwent permanent pacemaker implantation at 12 months based on the Reveal findings (6 HAVB/CHB, 3 severe bradycardia).

Conclusion: S3 valve recipients with new-onset LBBB have a high arrhythmic burden, with more than one-third of patients exhibiting at least 1 significant arrhythmic episode within 12 months (HAVB/CHB in 10% of patients). About one-half of bradyarrhythmic events occurred within 4 weeks after discharge. These results should inform future strategies on the use of continuous electrocardiographic monitoring in TAVR S3 patients with new conduction disturbances following the procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2021.05.031DOI Listing

Publication Analysis

Top Keywords

patients new-onset
16
patients
11
late arrhythmias
8
arrhythmias patients
8
new-onset persistent
8
left bundle
8
bundle branch
8
branch block
8
transcatheter aortic
8
aortic valve
8

Similar Publications

Risk prediction of new-onset thrombocytopenia in patients with systemic lupus erythematosus: a multicenter prospective cohort study based on Chinese SLE treatment and research group (CSTAR) registry.

Arthritis Res Ther

December 2024

Department of Rheumatology and Clinical Immunology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Dermatologic and Immunologic Diseases (NCRC-DID), Ministry of Science & Technology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Key Laboratory of Rheumatology and Clinical Immunology, Ministry of Education, Beijing, China.

Background: Thrombocytopenia (TP) is a hematological manifestation of systemic lupus erythematosus (SLE) and is associated with unfavorable prognostic outcomes. This study aimed to develop a risk prediction model for new-onset TP in SLE patients.

Methods: Based on the multicenter prospective Chinese SLE Treatment and Research Group (CSTAR) registry, newly diagnosed SLE patients without TP at registration were enrolled.

View Article and Find Full Text PDF

This population-based cohort study aimed to evaluate the risk of osteoporosis and fractures associated with higher-potency statin use compared to lower-potency statin use in patients with stroke, using data from the Health Insurance and Review Assessment database of South Korea (2010-2019). Patients who received statin within 30 days after hospitalization for a new-onset stroke (n = 276,911) were divided into higher-potency (n = 212,215, 76.6%) or lower-potency (n = 64,696, 23.

View Article and Find Full Text PDF

Objectives: To explore the efficacy of ofatumumab in new onset narcolepsy type 1 following SARS-CoV-2 infection.

Methods: We present a 9-year-old girl who experienced new onset narcolepsy type 1 following SARS-CoV-2 infection. Polysomnography (PSG) followed by a daytime multiple sleep latency test (MSLT) was under taken after admission.

View Article and Find Full Text PDF

Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.

Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.

View Article and Find Full Text PDF

Background: Immunotherapy, including the use of immune checkpoint inhibitors such as nivolumab, is increasingly common in cancer treatment and can lead to various immune-related adverse effects, including rare cases of diabetic ketoacidosis. This case report highlights an unique instance of nivolumab-induced diabetic ketoacidosis in a patient without prior history of diabetes, emphasizing the importance of careful monitoring even in those without traditional risk factors.

Case Presentation: We report a case of a 70-year-old Caucasian male with metastatic esophageal adenocarcinoma who developed diabetic ketoacidosis 3 weeks after stopping nivolumab therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!