Significance: The performance of the Eye Refract (Luneau Technology, Chartres, France), a new instrument to perform aberrometry-based automated subjective refraction, has been previously evaluated in healthy subjects. However, its clinical implications in other ocular conditions are still unknown.

Purpose: The purpose of this study was to evaluate the agreement between the Eye Refract and the traditional subjective refraction, as the criterion standard, in keratoconus patients with and without intracorneal ring segments (ICRSs).

Methods: A total of 50 eyes of 50 keratoconus patients were evaluated, dividing the sample into 2 groups: 27 eyes without ICRS (37.78 ± 9.35 years) and 23 eyes with ICRS (39.26 ± 13.62 years). An optometrist conducted the refraction with the Eye Refract, and another different optometrist conducted the traditional subjective refraction on the same day. Spherical equivalent (M), cylindrical vectors (J0 and J45), and corrected distance visual acuity were compared between both methods of refraction. In addition, Bland-Altman analysis was performed to assess the agreement between both methods of refraction.

Results: There were no statistically significant differences (P ≥ .05) between the Eye Refract and the traditional subjective refraction for all the variables under study in either group. Without ICRS, the mean difference and 95% limits of agreement (upper, lower) were -0.20 (+1.50, -1.89) D for M, -0.14 (+1.40, -1.68) D for J0, and +0.05 (+1.23, -1.14) D for J45. With ICRS, these values worsened to -0.62 (+3.89, -5.12) D for M, +0.06 (+2.46, -2.34) D for J0, and -0.02 (+2.23, -2.28) D for J45.

Conclusions: The Eye Refract seems to offer similar results compared with the traditional subjective refraction in keratoconus patients not implanted with ICRS. However, some patients could show abnormal measurements, especially those with ICRS, who should be treated with caution in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000001710DOI Listing

Publication Analysis

Top Keywords

subjective refraction
28
traditional subjective
20
eye refract
20
keratoconus patients
16
refraction
9
automated subjective
8
refraction keratoconus
8
refract traditional
8
eyes icrs
8
optometrist conducted
8

Similar Publications

Impact of central corneal astigmatism on postoperative visual outcomes in patients undergoing trifocal intraocular lens implantation.

BMC Ophthalmol

January 2025

Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.

Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.

Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.

View Article and Find Full Text PDF

Tooth shade selection is a fundamental factor in the success of dental restorations, and visual impairment may adversely affect this process. The aim of this cross-sectional clinical study was to determine whether visual impairment influences shade selection using two methods: spectrophotometry and shade guides. : The sample consisted of 2796 maxillary and mandibular teeth, and shade selection was measured subjectively with a shade guide (VITA Classic, VITA Zahnfabrik) and objectively with a spectrophotometer (VITA Easyshade V, VITA Zahnfabrik, Bad Säckingen, Germany).

View Article and Find Full Text PDF

Significance: Epidemiological information about the epiretinal membrane is important for better clinical management and understanding of the nature and burden of this disease. There are some gaps in our understanding of the epidemiology of epiretinal membranes, particularly in Africa and the Middle East.

Purpose: This study aimed to determine the prevalence and risk factors of epiretinal membrane using spectral-domain optical coherence tomography (OCT) in an Iranian elderly population.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.

View Article and Find Full Text PDF

Background: Contrast sensitivity is an important measure of vision quality. Risk of falling injury is strongly associated with poor contrast sensitivity compared with poor near- and distance visual acuity. Since good visual acuity is not necessarily associated with good visual performance in the "real world" it is important to consider contrast sensitivity when prescribing corrective lenses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!