Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To report a novel technique for refixation of the dislocated CZ70BD intraocular lens.
Methods: Posterior vitrectomy is performed with a 23-gauge or 25-gauge pars plana vitrectomy system with chandelier illumination. One needle of a double-arm 9-0 prolene needle is passed through the sclera 1.5 mm postlimbus. The needle is retrieved through the corneal paracentesis using a 27-G needle, and the suture is then cut. The suture end is passed through the eyelet of the dislocated CZ70BD intraocular lens inside the vitreous cavity. This is aided with a pair of 27-G MaxGrip forceps, which is inserted through a 27-G sclerostomy site at the intended scleral outlet. After passing the suture through the eyelet, the suture is pulled out at the 27-G sclerostomy site and a knot is tied and rotated. Similar procedure is performed for the second haptic if necessary.
Results: Seven eyes were successfully operated on using this technique with a mean follow-up of 12.4 months. There was significant improvement in the best-corrected visual acuity after the operation ( P = 0.016). Postoperative intraocular lens centration and alignment were satisfactory. One patient developed macula-on retinal detachment 1 month after the operation, which was successfully repaired without loss in the best-corrected visual acuity.
Conclusion: The described novel technique is effective for refixation of dislocated CZ70BD intraocular lens.