Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS). A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed. All EUS-GEs were performed using a cautery-enhanced LLAMS. Thirty-three patients were referred for endoscopic management of GOO. Two patients were excluded due to a lack of an adequate window for EUS-GE. The remaining 31 patients (93.94 %) (mean age: 61.35 ± 16.52 years; 54.84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO. Technical success was achieved in all patients (100 %) with attempted EUS-GE. Complete clinical success (tolerance of regular diet) was achieved in 93.55 % of patients (n = 29). Two patients (6.45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids. Overall mean follow-up was 140.84 ± 160.41 days (median 70, range 4-590). All stents remained patent with no evidence of recurrent GOO symptoms. One patient (3.23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy. EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet. Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8159608 | PMC |
http://dx.doi.org/10.1055/a-1399-8442 | DOI Listing |
Endosc Int Open
June 2021
Division of Gastroenterology and Hepatology, University of New Mexico, Albuquerque, New Mexico, United States.
Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!