Background: Endoscopic ultrasound-guided drainage is suggested as the first approach in the management of symptomatic and complex walled-off pancreatic necrosis. Dual approach with percutaneous drainage could be the best choice when the necrosis is deep extended till the pelvic paracolic gutter; however, the available catheter could not be large enough to drain solid necrosis neither to perform necrosectomy, entailing a higher need for surgery. Therefore, percutaneous endoscopic necrosectomy through a large bore percutaneous self-expandable metal stent has been proposed.

Case Presentation: In this study, we present the case of a 61-year-old man admitted to our hospital with a history of sepsis and persistent multiorgan failure secondary to walled-off pancreatic necrosis due to acute necrotizing pancreatitis. Firstly, the patient underwent transgastric endoscopic ultrasound-guided drainage using a lumen-apposing metal stent and three sessions of direct endoscopic necrosectomy. Because of recurrence of multiorgan failure and the presence of the necrosis deeper to the pelvic paracolic gutter at computed tomography scan, we decided to perform percutaneous endoscopic necrosectomy using an esophageal self-expandable metal stent. After four sessions of necrosectomy, the collection was resolved without complications. Therefore, we perform a revision of the literature, in order to provide the state-of-art on this technique. The available data are, to date, derived by case reports and case series, which showed high rates both of technical and clinical success. However, a not negligible rate of adverse events has been reported, mainly represented by fistulas and abdominal pain.

Conclusion: Dual approach, using lumen apposing metal stent and percutaneous self-expandable metal stent, is a compelling option of treatment for patients affected by symptomatic, complex walled-off pancreatic necrosis, allowing to directly remove large amounts of necrosis avoiding surgery. Percutaneous endoscopic necrosectomy seems a promising technique that could be part of the step-up-approach, before emergency surgery. However, to date, it should be reserved in referral centers, where a multidisciplinary team is disposable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8170826PMC
http://dx.doi.org/10.1186/s13017-021-00367-yDOI Listing

Publication Analysis

Top Keywords

metal stent
24
endoscopic necrosectomy
20
percutaneous endoscopic
16
dual approach
12
complex walled-off
12
walled-off pancreatic
12
pancreatic necrosis
12
self-expandable metal
12
lumen apposing
8
apposing metal
8

Similar Publications

Background And Aims: Gastric outlet obstruction (GOO) is a clinical manifestation of mechanical obstruction at the antropyloric region or proximal small bowel. The goal of endoscopic management is to relieve the obstruction so patients can resume per oral intake. Most studies have focused on malignant causes of GOO; yet only a handful have explored outcomes related to benign etiologies.

View Article and Find Full Text PDF

Neointimal coverage and stent apposition, as assessed from intravascular optical coherence tomography (IVOCT) images, are crucial for optimizing percutaneous coronary intervention (PCI). Existing state-of-the-art computer algorithms designed to automate this analysis often treat lumen and stent segmentations as separate target entities, applicable only to a single stent type and overlook automation of preselecting which pullback segments need segmentation, thus limit their practicality. This study aimed for an algorithm capable of intelligently handling the entire IVOCT pullback across different phases of PCI and clinical scenarios, including the presence and coexistence of metal and bioresorbable vascular scaffold (BVS), stent types.

View Article and Find Full Text PDF

Objectives: We aim to evaluate the safety and effectiveness of the Zenith Dissection Endovascular System (ZDES; Zenith TX2 Dissection Endovascular Graft with Pro-Form and Zenith Dissection Endovascular Stent), which uses a proximal stent graft along with a distal bare metal stent compared to traditional stent grafts in the repair of acute, complicated Type B Aortic Dissection (AcTBAD).

Methods: This retrospective study reviews the medical charts of 32 patients with AcTBAD repaired at a single urban academic medical center. 16 of these AcTBAD cases were repaired with the ZDES (87.

View Article and Find Full Text PDF

Baicalin-based composite coating for achieving biological multifunctionality of vascular stents.

J Control Release

January 2025

Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu 610031, PR China. Electronic address:

Vascular stents are frequently used in interventional therapy for atherosclerotic arteries. Interventional treatment with bare metal stents and drug-eluting stents has significantly reduced mortality. Restenosis and late thrombus were also major safety concerns in stent implantation.

View Article and Find Full Text PDF

Introduction: Auto-expandable ureteral stents can be an alternative to percutaneous nephrostomy (PCN) in refractory ureteral stenosis. Our aim is to analyse results and complications of ureteral stents in our centre.

Methods: Retrospective review of OptiMed® expandable ureteral stents placed in our centre (1996-2022).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!