A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study. | LitMetric

Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes.

Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model.

Results: During both experiments an increase in FLV (initial experiment: ΔFLV = 2.05 ml, , repeated experiment: ΔFLV = 1.08 ml, ) and peak WSS (initial experiment: ΔWSS = 1.2 Pa, , repeated experiment: ΔWSS = 1.79 Pa, ) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV () was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; ) and non-significant during repeated experiment (3.22 to 4.00 Pa; ).

Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15385744211017117DOI Listing

Publication Analysis

Top Keywords

false lumen
24
flow mri
16
increase flv
12
repeated experiment
12
flow
9
wall shear
8
shear stress
8
acute type
8
type aortic
8
aortic dissection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!