Computerized technologies informing cardiac catheterization and guiding coronary intervention.

Am Heart J

Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary, University of London, London; Institute of Cardiovascular Sciences, University College London, London. Electronic address:

Published: October 2021

Advances in image processing and computer hardware have enabled the development of user-friendly software which operate in real-time and can be used in the catheterization laboratory to facilitate percutaneous coronary intervention (PCI). The two dimensional-(2D) quantitative coronary angiography (QCA) systems that have traditionally been used to assess lesion severity have been replaced by 3D-QCA systems, enabling more reliable evaluation of vessel geometry and lesion dimensions. This also allows 3D reconstruction of coronary bifurcation anatomy and generation of models that can be processed by computational fluid dynamic techniques to reliably detect flow-limiting lesions. More recently, software has been introduced that has the capability of generating a digital silhouette of the coronary arteries superimposed onto X-ray angiography to facilitate wire crossing and stent placement, and potentially reduce contrast use. In parallel, methodologies have been developed that operate with an accessible interface and can process intravascular imaging data, reliably quantify lesion severity and co-register intravascular and X-ray angiographic data to comprehensively assess plaque distribution and guide PCI. The above advances are used in daily practice to improve procedural results and outcomes. This review aims to provide an overview of the developments in the field - it presents the computer-based technologies that have been designed to accurately assess lesion severity, summarizes the advantages and limitations of the systems introduced to co-register imaging data and discusses the potential value of the existing and emerging software in the catheterization laboratory.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ahj.2021.05.017DOI Listing

Publication Analysis

Top Keywords

lesion severity
12
coronary intervention
8
catheterization laboratory
8
assess lesion
8
imaging data
8
coronary
5
computerized technologies
4
technologies informing
4
informing cardiac
4
cardiac catheterization
4

Similar Publications

Dual-energy CT-derived virtual noncalcium imaging to assess bone marrow lesions in patients with knee osteoarthritis.

Sci Rep

January 2025

Department of Radiology, The First Affiliated Hospital, Hengyang Medical School, University of South China, Chuanshan Road No. 69, Hengyang, 421001, Hunan, China.

To determine the diagnostic performance of dual-energy CT (DECT) virtual noncalcium (VNCa) technique in the detection of bone marrow lesions (BMLs) in knee osteoarthritis, and further analyze the correlation between the severity of BMLs on VNCa image and the degree of knee pain. 23 consecutive patients with clinically diagnosed knee osteoarthritis were underwent DECT and 3.0T MRI between August 2017 and November 2018.

View Article and Find Full Text PDF

Introduction: Our previous work demonstrated that evaluating large ischemic cores using the apparent diffusion coefficient (ADC) could predict EVT outcomes, with the most frequent ADC (peak ADC) ≥520×10 mm/s associated with better clinical results. Since the degree of ADC reduction reflects the severity of ischemic stress, this study aimed to assess the utility of an ADC color map in visualizing this stress.

Patients And Methods: This retrospective cohort study included consecutive patients with a low Alberta Stroke Program Early Computed Tomography Score (ASPECTS) using diffusion-weighted imaging (DWI) who underwent successful EVT recanalization between April 2014 and March 2023.

View Article and Find Full Text PDF

Rosacea-like skin reaction under treatment with dupilumab for atopic dermatitis.

J Dermatolog Treat

December 2025

Institute for Health Services Research in Dermatology and Nursing (IVDP), University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany.

Purpose: Dupilumab is a widely recommended treatment for moderate-to-severe atopic dermatitis (AD), with known ocular side effects but less frequent cutaneous reactions.

Material And Methods: This case report details a 52-year-old female patient with atopic dermatitis treated with dupilumab. After an initially successful treatment, the patient developed a rosacea-like dermatitis.

View Article and Find Full Text PDF

Recent outbreaks of PRRSV in live attenuated vaccine-immunized pig farms in Tianjin, China have raised questions about the etiological characteristics and pathogenicity of the PRRSV variant, which remains unknown. In this study, a multiple lineages recombinant PRRSV strain named TJ-C6, was isolated and identified. Phylogenetic trees and genome homology analyses revealed that TJ-C6 belonged to lineage 1.

View Article and Find Full Text PDF

When Are Single Reader Evaluations Insufficient in Teledermoscopic Assessments? Analyses of a Retrospective Cohort Study.

Telemed J E Health

January 2025

Department of Clinical Sciences, Dermatology and Venereology, Lund Skin Cancer Research Group, Lund University, Lund, Sweden.

Teledermoscopy (TDS) emerges as an efficient tool for diagnosing skin lesions. In Sweden, double reading is the standard of care, but risk factors for misdiagnosis or mismanagement using single reader evaluations (SRE) are not well-studied. This study aimed to assess the accuracy of SRE compared with the gold standard in TDS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!