Objectives: To collect and analyse the available evidence in the outcomes of patients treated with fenestrated endovascular aortic repair (f-EVAR) technique focusing specifically on visceral vessel outcomes.

Methods: The current meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All the studies reporting the f-EVAR technique for the management of degenerative pararenal and/or type IV thoracoabdominal aortic aneurysms (TAAA) were considered eligible for inclusion in the study. The main study outcomes (technical success, type I endoleaks, fracture or occlusion of the bridging stents, overall aneurysm-related mortality, and the reintervention rate) were subsequently expressed as proportions and 95% confidence intervals.

Results: Fourteen studies with a total of 1804 patients were included in a pooled analysis. The technical success of the procedure was 95.97% (95%CI = 92.35-98.60). Intraoperatively, the pooled proportion of reported type I endoleak was 7.6% (95%CI = 2.52-14.60) while during a median follow-up of 41 months (range 11-96) follow-up period the pooled rate of fracture and occlusion of the bridging stents was 2.79% (95%CI = 0.00-8.52) and 4.46% (95%CI = 1.93-7.77), respectively. The overall aneurysm-related mortality was detected to be 0.63% (95%CI = 0.04-1.63), and the pooled estimate for re-intervention rate was 15.69%.

Conclusions: Fenestrated endovascular repair for p-AAA is an effective and safe treatment. Target vessel complications and endoleaks remain the two most important concerns for fenestrated endovascular procedures, contributing to most of the secondary interventions. The lack of computed tomography angiography follow-up evaluation does not allow us to draw robust conclusions about the complication rates for the superior mesenteric artery during f-EVAR. Due to the potential implications of SMA complications on aneurysm-related mortality, standardized reporting of short- and long-term target visceral vessel outcomes is required.

Download full-text PDF

Source
http://dx.doi.org/10.1177/17085381211019148DOI Listing

Publication Analysis

Top Keywords

fenestrated endovascular
16
aneurysm-related mortality
12
standardized reporting
8
endovascular aortic
8
aortic repair
8
f-evar technique
8
visceral vessel
8
technical success
8
fracture occlusion
8
occlusion bridging
8

Similar Publications

Purpose: To report a case series on using a novel semi-branch feature in custom-made stent-grafts in the endovascular treatment of complex aortic aneurysms and summarize the contemporary usage of this technology.

Case Series: Four patients underwent endovascular aortic aneurysm repair (EVAR) with a custom-made semi-branch stent-graft (Semi-Branch Endovascular Aortic Aneurysm Repair [SBEVAR]). Two male patients, 75- and 76-year-old, were treated due to failed EVAR with late-type Ia endoleak, and the other two, 80- and 55-year-old male patients, due to a juxta-renal aortic abdominal aneurysm (JRAAA).

View Article and Find Full Text PDF

Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!