The plaque reduction neutralization test (PRNT) is a preferred method for the detection of functional, SARS-CoV-2 specific neutralizing antibodies from serum samples. Alternatively, surrogate enzyme-linked immunosorbent assays (ELISAs) using ACE2 as the target structure for the detection of neutralization-competent antibodies have been developed. They are capable of high throughput, have a short turnaround time, and can be performed under standard laboratory safety conditions. However, there are very limited data on their clinical performance and how they compare to the PRNT. We evaluated three surrogate immunoassays (GenScript SARS-CoV-2 Surrogate Virus Neutralization Test Kit (GenScript Biotech, Piscataway Township, NJ, USA), the TECO SARS-CoV-2 Neutralization Antibody Assay (TECOmedical AG, Sissach, Switzerland), and the Leinco COVID-19 ImmunoRank™ Neutralization MICRO-ELISA (Leinco Technologies, Fenton, MO, USA)) and one automated quantitative SARS-CoV-2 Spike protein-based IgG antibody assay (Abbott GmbH, Wiesbaden, Germany) by testing 78 clinical samples, including several follow-up samples of six BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA) vaccinated individuals. Using the PRNT as a reference method, the overall sensitivity of the examined assays ranged from 93.8 to 100% and specificity ranged from 73.9 to 91.3%. Weighted kappa demonstrated a substantial to almost perfect agreement. The findings of our study allow these assays to be considered when a PRNT is not available. However, the latter still should be the preferred choice. For optimal clinical performance, the cut-off value of the TECO assay should be individually adapted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8157164PMC
http://dx.doi.org/10.3390/jcm10102128DOI Listing

Publication Analysis

Top Keywords

surrogate enzyme-linked
8
enzyme-linked immunosorbent
8
immunosorbent assays
8
neutralizing antibodies
8
neutralization test
8
prnt preferred
8
clinical performance
8
antibody assay
8
sars-cov-2
5
utility surrogate
4

Similar Publications

Background: The emergence of new SARS-CoV-2 variants poses a new challenge for the treatment of immunocompromised patients against COVID-19. In this context, high titer COVID-19 Convalescent Plasma (CCP) is one of the few available therapeutics for these patients. We have revisited the selection of CCP samples and its efficacy against Omicron XBB.

View Article and Find Full Text PDF

Quantification of serum daratumumab in multiple myeloma patients by LC-MS/MS, comparison with ELISA.

J Pharm Biomed Anal

December 2024

Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201210, China; University of Chinese Academy of Sciences, Beijing 100049, China. Electronic address:

Daratumumab is a fully human immunoglobulin G1 monoclonal antibody employed for treating relapsed/refractory multiple myeloma and light-chain amyloidosis. Quantifying monoclonal antibodies in serum presents challenges due to interference from biological matrices. This research aimed to develop and verify an liquid chromatography tandem-mass spectrometry (LC-MS/MS) approach for quantifying serum daratumumab, employing immunoglobulin G purification without alkylation, and to assess its applicability in patients with multiple myeloma receiving intravenous daratumumab.

View Article and Find Full Text PDF

Here we show that when using a mix of 274 light synthetic peptide standards (NAT) as surrogates for 270 human plasma proteins, as well as stable isotope-labelled standards (SIS) as normalizers (both from MRM Proteomics Inc.) for targeted quantitative analysis by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS), the Seer Proteograph™ platform allowed for the enrichment and absolute quantitation of up to an additional 62 targets (median) compared to two standard proteomic workflows without enrichment, representing an increase of 44%. The nanoparticle-based fractionation workflow resulted in improved reproducibility compared to a traditional proteomic workflow with no fractionation (median 8.

View Article and Find Full Text PDF

Detection of SARS-CoV-2- specific antibodies in domestic cats using different ELISA tests.

J Virol Methods

December 2024

Veterinary Diagnostic Laboratory, College of Veterinary Medicine, Kansas State University, Manhattan, KS, USA; Department of Diagnostic Medicine/Pathobiology, College of Veterinary Medicine, Kansas State University, Manhattan, KS, USA. Electronic address:

The emergence of SARS-CoV-2 raised concerns about the potential for interspecies transmission, particularly among domestic animals. We evaluated the seroprevalence of SARS-CoV-2 antibodies in domestic cats from various sites in North America. A total of 216 serum samples collected between December 2019 and February 2022, were analyzed using four different enzyme-linked immunosorbent assays (ELISAs), including a commercial surrogate virus neutralization test (sVNT), a commercial double antigen test (dN ELISA), and two in-house developed indirect ELISAS based on receptor-binding domain (RBD iELISA) and the nucleocapsid (N iELISA) proteins, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • * ELISA has been suggested as an easier alternative but struggles with antigen availability, particularly RABV glycoprotein, which requires high biosafety levels for use.
  • * The research tested insect cell extracts producing RABV glycoprotein and found it effectively detected rabies antibodies in vaccinated dogs, with a 90.48% sensitivity and 80.00% specificity, making it suitable for quick screening and monitoring vaccination efforts.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!