The immediate refrigeration of meat after slaughter is a key issue for the proper storage and aging of meat. The industry standard cold chain relies on low temperatures and ventilation to lower the internal carcass temperature to 0-4 °C within the first 48 h, i.e., within four times the so-called semi-cooling time. On the other hand, for games, once bled and eviscerated, the carcass must be sent to a point where it can be sectioned or kept on air for maturation at refrigeration temperature. The precautions to observe are few and simple but essential: protect the meat and start the cooling process quickly. After preparing the animal (bleeding and evisceration), it may be necessary to face a period of transport that is sometimes long and not very easy; while small animals can be easily transported in a backpack, larger ones must necessarily be carried by several people or sometimes dragged to the vehicle capable of transporting them. It is obvious that a wild boar opened from the jaws to the pelvis and dragged for hundreds of meters will tend to be contaminated, although these contaminations are to be considered secondary for the preservation of the meat, compared to contamination by the intestinal contents. In an attempt to investigate the effect of delayed refrigeration on wild boar carcass contamination, the aim of this work was to determine a correlation between several hunting and logistic parameters (age, sex, animal weight, shooting distance, number of shots, weather and temperature and time from shot to refrigeration and to analysis) and bacterial contamination of the carcass. The correlation coefficient, r, was found to be 0.038 for the eviscerated body weight ( < 0.05), 0.091 for the external temperature on the day of hunting ( < 0.05), 0.027 for the time from shot to refrigeration ( = 0.081), 0.038 for the time from refrigeration to analysis ( < 0.05) and 0.043 for the time from shot to analysis ( < 0.05). These results stand for a negative correlation between the bacterial population and eviscerated carcass weight and between the bacterial population and external temperature and for a positive correlation between the time from shot to analysis and from refrigeration to analysis. No association was demonstrated between the bacterial population and the time from shot to refrigeration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8156622 | PMC |
http://dx.doi.org/10.3390/ani11051434 | DOI Listing |
Nat Commun
January 2025
Institute of Theoretical Computer Science, Graz University of Technology, Graz, Austria.
HardwareX
March 2025
LIGHT Community, Physics Department, Imperial College London SW7 2AZ, UK.
We recently demonstrated polarisation differential phase contrast microscopy () as a robust, low-cost single-shot implementation of (semi)quantitative phase imaging based on differential phase microscopy. utilises a polarisation-sensitive camera to simultaneously acquire four obliquely transilluminated images from which phase images mapping spatial variation of optical path difference can be calculated. microscopy can be implemented on existing or bespoke microscopes and can utilise radiation at a wide range of visible to near infrared wavelengths and so is straightforward to integrate with fluorescence microscopy.
View Article and Find Full Text PDFThe technique of spectral polarization imaging (SPI) is a potent detection tool in various fields due to its ability to capture multi-dimensional information. However, existing SPI systems usually face challenges associated with architectural complexity and computational requirements, rendering them unsuitable for handheld, on-board, and real-time applications. Consequently, a compact single-shot multispectral polarization imager (CSMPI) is proposed, which employs a combined spectral-polarization encoding strategy to address the aforementioned issues.
View Article and Find Full Text PDFWe demonstrate PaCMAN, a ptychography algorithm that can reconstruct high quality images with broadband illumination sources while being robust to shot, detector, and parasitic noise. We extend prior monochromatization work to improve accuracy, especially for discrete spectra, and also demonstrate how PaCMAN can be converted into Ms. PaCMAN, a multi-spectral variant that outperforms multi-spectral ePIE.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Department of Radiology, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine (Shenzhen Traditional Chinese Medicine Hospital), Shenzhen, China.
Background: Multifrequency MR elastography (mMRE) enables noninvasive quantification of renal stiffness in patients with chronic kidney disease (CKD). Manual segmentation of the kidneys on mMRE is time-consuming and prone to increased interobserver variability.
Purpose: To evaluate the performance of mMRE combined with automatic segmentation in assessing CKD severity.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!