We present a method to produce small pitch gratings for X-ray interferometric imaging applications, allowing the phase sensitivity to be increased and/or the length of the laboratory setup to be minimized. The method is based on fabrication of high aspect ratio silicon microstructures using deep reactive ion etching (Bosch technique) of dense grating arrays and followed by conformal electroplating of Au. We demonstrated that low resistivity Si substrates (<0.01 Ohm·cm) enable the metal seeding layer deposition step to be avoided, which is normally required to initiate the electroplating process. Etching conditions were optimized to realize Si recess structures with a slight bottom tapering, which ensured the void-free Au filling of the trenches. Vapor HF was used to remove the native oxide layer from the Si grating surface prior to electroplating in the cyanide-based Au electrolyte. Fabrication of Au gratings with pitch in the range 1.2-3.0 µm was successfully realized. A substantial improved aspect ratio of 45:1 for a pitch size of 1.2 µm was achieved with respect to the prior art on 4-inch wafer-based technology. The fabricated Au gratings were tested with X-ray interferometers in Talbot-Laue configuration with measured visibility of 13% at an X-ray design energy of 26 keV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8147938PMC
http://dx.doi.org/10.3390/mi12050517DOI Listing

Publication Analysis

Top Keywords

interferometric imaging
8
fabrication x-ray
4
x-ray gratings
4
gratings interferometric
4
imaging conformal
4
conformal seedless
4
seedless gold
4
gold electroplating
4
electroplating method
4
method produce
4

Similar Publications

Globally scalable glacier mapping by deep learning matches expert delineation accuracy.

Nat Commun

January 2025

Department of Earth Observation Science, Faculty of Geo-information Science and Earth Observation (ITC), University of Twente, Overijssel, The Netherlands.

Accurate global glacier mapping is critical for understanding climate change impacts. Despite its importance, automated glacier mapping at a global scale remains largely unexplored. Here we address this gap and propose Glacier-VisionTransformer-U-Net (GlaViTU), a convolutional-transformer deep learning model, and five strategies for multitemporal global-scale glacier mapping using open satellite imagery.

View Article and Find Full Text PDF

X-ray dark-field imaging highlights sample structures through contrast generated by sub-resolution features within the inspected volume. Quantifying dark-field signals generally involves multiple exposures for phase retrieval, separating contributions from scattering, refraction, and attenuation. Here, we introduce an approach for non-interferometric X-ray dark-field imaging that presents a single-parameter representation of the sample.

View Article and Find Full Text PDF

Elucidating subcellular architecture and dynamics at isotropic 100-nm resolution with 4Pi-SIM.

Nat Methods

December 2024

Westlake Laboratory of Life Sciences and Biomedicine, Hangzhou, China.

Three-dimensional structured illumination microscopy (3D-SIM) provides excellent optical sectioning and doubles the resolution in all dimensions compared with wide-field microscopy. However, its much lower axial resolution results in blurred fine details in that direction and overall image distortion. Here we present 4Pi-SIM, a substantial revamp of IS that synergizes 3D-SIM with interferometric microscopy to achieve isotropic optical resolution through interference in both the illumination and detection wavefronts.

View Article and Find Full Text PDF

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored.

View Article and Find Full Text PDF

Extracellular vesicles (EVs) are pivotal in various biological processes and diseases, yet their small size and heterogeneity pose challenges for single EV quantification. We introduce interferometric electrochemical microscopy (iECM), a sensitive label-free technique that combines interferometric scattering and electrochemical impedance imaging. This method enables the quantification of the impedance of single EVs, providing unique insights into their electrochemical properties, and allows for the simultaneous measurement of size and real-time monitoring of antibody binding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!