AI Article Synopsis

Article Abstract

This article focuses on the output feedback control of single-link flexible-joint robot manipulators (SFJRMs) with matched disturbances and parametric uncertainties. Formally, four sensing elements are required to design the controller for single-link manipulators. We have designed a robust control technique for the semiglobal stabilization problem of the angular position of the link in the SFJRM system, with the availability of only a position sensing device. The sliding mode control (SMC) based output feedback controller is devised for SFJRM dynamics. The nonlinear model of SFJRM is considered to estimate the unknown states utilizing the high-gain observer (HGO). It is shown that the output under SMC using HGO-based estimated states coincides with that using original states when the gains of HGO are sufficiently high. Finally, the results are presented showing that the designed control technique works well when the SFJRM model is uncertain and matched perturbations are expected.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8125959PMC
http://dx.doi.org/10.3390/s21093252DOI Listing

Publication Analysis

Top Keywords

output feedback
12
feedback control
8
control single-link
8
single-link flexible-joint
8
flexible-joint robot
8
matched disturbances
8
control technique
8
control
5
robust output
4
robot manipulator
4

Similar Publications

Background: Cervical cancer disparities persist among minoritized women due to infrequent screening and poor follow-up. Structural and psychosocial barriers to following up with colposcopy are problematic for minoritized women. Evidence-based interventions using patient navigation and tailored telephone counseling, including the Tailored Communication for Cervical Cancer Risk (TC3), have modestly improved colposcopy attendance.

View Article and Find Full Text PDF

DNAzyme-based cascade networks are effective tools to achieve ultrasensitive detection of low-abundance miRNAs. However, their designs are complicated and costly, and the operation is time-consuming. Herein, a novel simple noncascade DNAzyme network is designed and its amplification effect is comparable to or even better than many cascading ones.

View Article and Find Full Text PDF

From Escalate to Elevate: A New Paradigm for Comprehensive Cardiogenic Shock Management.

Can J Cardiol

January 2025

Ted Rogers Centre for Heart Research, University Health Network, Toronto, ON, Canada; Division of Cardiology, Peter Munk Cardiac Centre, University Health Network, Toronto, ON, Canada. Electronic address:

Patients with cardiogenic shock (CS) present with critical hemodynamic compromise with low cardiac output (CO) resulting in end-organ dysfunction. Prognosis is closely related to the severity of shock and treatment of patients with CS is resource intensive. In this review, we consider the current treatment paradigms alongside the evidence that underpins them.

View Article and Find Full Text PDF

Forests have the potential to contribute significantly to global climate policy efforts through enhanced carbon sequestration and storage in terrestrial systems and wood products. Projections models simulate changes future in forest carbon fluxes under different environmental, economic, and policy conditions and can inform landowners and policymakers on how to best utilize global forests for mitigating climate change. However, forest carbon modeling frameworks are often developed and applied in a highly disciplinary manner, e.

View Article and Find Full Text PDF

Improving Real-Time Feedback During Cochlear Implantation: The Auditory Nerve Neurophonic/Cochlear Microphonic Ratio.

Ear Hear

January 2025

Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.

Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!