Cooperative Fusion Based Passive Multistatic Radar Detection.

Sensors (Basel)

School of Engineering, RMIT University, Melbourne 3000, Australia.

Published: May 2021

Passive multistatic radars have gained a lot of interest in recent years as they offer many benefits contrary to conventional radars. Here in this research, our aim is detection of target in a passive multistatic radar system. The system contains a single transmitter and multiple spatially distributed receivers comprised of both the surveillance and reference antennas. The system consists of two main parts: 1. Local receiver, and 2. Fusion center. Each local receiver detects the signal, processes it, and passes the information to the fusion center for final detection. To take the advantage of spatial diversity, we apply major fusion techniques consisting of hard fusion and soft fusion for the case of multistatic passive radars. Hard fusion techniques are analyzed for the case of different local radar detectors. In terms of soft fusion, a blind technique called equal gain soft fusion technique with random matrix theory-based local detector is analytically and theoretically analyzed under null hypothesis along with the calculation of detection threshold. Furthermore, six novel random matrix theory-based soft fusion techniques are proposed. All the techniques are blind in nature and hence do not require any knowledge of transmitted signal or channel information. Simulation results illustrate that proposed fusion techniques increase detection performance to a reasonable extent compared to other blind fusion techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8125025PMC
http://dx.doi.org/10.3390/s21093209DOI Listing

Publication Analysis

Top Keywords

fusion techniques
20
soft fusion
16
passive multistatic
12
fusion
11
multistatic radar
8
local receiver
8
fusion center
8
hard fusion
8
random matrix
8
matrix theory-based
8

Similar Publications

Background: Robotic assistance has become increasingly prevalent in spinal surgery in recent years, emerging as a tool to increase accuracy and precision and lower complication rates and radiation exposure. The 7 and 8 Annual Seattle Science Foundation (SSF) Robotics Courses showcased presentations and demonstrations from some of the field's most experiences leaders on latest topics in robotics and spinal surgery, including cutting-edge preoperative planning technologies, augmented reality (AR) in the operating room, cervical fusion with transpedicular screws, and neuro-oncologic management. We provide a scoping review of the use of robotics technology in spinal surgery featuring highlights from the 7 and 8 Annual SSF Robotics Courses.

View Article and Find Full Text PDF

Background: It has been more than a decade since fusion prostate biopsy (FPB) has been used in the diagnosis of prostate cancer (PCa). Therefore, patients with a previous history of negative FPB and ongoing suspicion of PCa are beginning to emerge. This study investigated whether the first biopsy type (standard or fusion) should be effective in deciding on a second biopsy.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Background: Robotic-assisted spinal surgery has reportedly improved the accuracy of instrumentation with smaller incisions, improving surgical outcomes and reducing hospital stay. However, robot-assisted spine surgery has thus far been confined to placement of pedicle screw instrumentation only. This pilot study aims to explore the feasibility of utilizing the Mazor™ X Stealth Edition (Medtronic, Sofamor Danek USA), robotic-arm platform in the minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) procedure inclusive of interbody cage placement, in our institution.

View Article and Find Full Text PDF

Anterior lumbar interbody fusion (ALIF) is an anterior surgical approach for interbody fusion in the lumbar spine which affords the surgeon unfettered access to the disc space and allows for release of the anterior longitudinal ligament and insertion of a large, lordotic interbody graft. Despite the benefits associated with ALIF when compared with other lumbar interbody fusion techniques, the ALIF approach is associated with a number of unique complications, and certain patient-specific criteria (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!