Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed!
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The development of sensitive methods for the determination of potential bacterial contamination is of upmost importance for environmental monitoring and food safety. In this study, we present a new method combining a fast pre-enrichment step using a microporous cryogel and a detection and identification step using antimicrobial peptides (AMPs) and labelled antibodies, respectively. The experimental method consists of: (i) the capture of large amounts of bacteria from liquid samples by using a highly porous and functionalized cryogel; (ii) the detection and categorisation of Gram-positive and Gram-negative bacteria by determining their affinities toward a small set of AMPs; and (iii) the identification of the bacterial strain by using labelled detection antibodies. As proof of concept, the assessment of the three steps of the analysis was performed by using and as models for Gram-negative and Gram-positive bacteria, respectively. The use of AMPs with broad specificity combined with labelled antibodies enabled the detection and potential categorization of a large spectrum of unknown or unexpected bacteria.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8147366 | PMC |
http://dx.doi.org/10.3390/bios11050142 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!