A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-sensitivity troponin assays for early rule-out of acute myocardial infarction in people with acute chest pain: a systematic review and economic evaluation. | LitMetric

Background: Early diagnosis of acute myocardial infarction is important, but only 20% of emergency admissions for chest pain will actually have an acute myocardial infarction. High-sensitivity cardiac troponin assays may allow rapid rule out of myocardial infarction and avoid unnecessary hospital admissions.

Objectives: To assess the clinical effectiveness and cost-effectiveness of high-sensitivity cardiac troponin assays for the management of adults presenting with acute chest pain, in particular for the early rule-out of acute myocardial infarction.

Methods: Sixteen databases were searched up to September 2019. Review methods followed published guidelines. Studies were assessed for quality using appropriate risk-of-bias tools. The bivariate model was used to estimate summary sensitivity and specificity for meta-analyses involving four or more studies; otherwise, random-effects logistic regression was used. The health economic analysis considered the long-term costs and quality-adjusted life-years associated with different troponin testing methods. The de novo model consisted of a decision tree and a state-transition cohort model. A lifetime time horizon (of 60 years) was used.

Results: Thirty-seven studies (123 publications) were included in the review. The high-sensitivity cardiac troponin test strategies evaluated are defined by the combination of four factors (i.e. assay, number and timing of tests, and threshold concentration), resulting in a large number of possible combinations. Clinical opinion indicated a minimum clinically acceptable sensitivity of 97%. When considering single test strategies, only those using a threshold at or near to the limit of detection for the assay, in a sample taken at presentation, met the minimum clinically acceptable sensitivity criterion. The majority of the multiple test strategies that met this criterion comprised an initial rule-out step, based on high-sensitivity cardiac troponin levels in a sample taken on presentation and a minimum symptom duration, and a second stage for patients not meeting the initial rule-out criteria, based on presentation levels of high-sensitivity cardiac troponin and absolute change after 1, 2 or 3 hours. Two large cluster randomised controlled trials found that implementation of an early rule-out pathway for myocardial infarction reduced length of stay and rate of hospital admission without increasing cardiac events. In the base-case analysis, standard troponin testing was both the most effective and the most costly. Other testing strategies with a sensitivity of 100% (subject to uncertainty) were almost equally effective, resulting in the same life-year and quality-adjusted life-year gain at up to four decimal places. Comparisons based on the next best alternative showed that for willingness-to-pay values below £8455 per quality-adjusted life-year, the Access High Sensitivity Troponin I (Beckman Coulter, Brea, CA, USA) [(symptoms > 3 hours AND < 4 ng/l at 0 hours) OR (< 5 ng/l AND Δ < 5 ng/l at 0 to 2 hours)] would be cost-effective. For thresholds between £8455 and £20,190 per quality-adjusted life-year, the Elecsys Troponin-T high sensitive (Roche, Basel, Switzerland) (< 12 ng/l at 0 hours AND Δ < 3 ng/l at 0 to 1 hours) would be cost-effective. For a threshold > £20,190 per quality-adjusted life-year, the Dimension Vista High-Sensitivity Troponin I (Siemens Healthcare, Erlangen, Germany) (< 5 ng/l at 0 hours AND Δ < 2 ng/l at 0 to 1 hours) would be cost-effective.

Conclusions: High-sensitivity cardiac troponin testing may be cost-effective compared with standard troponin testing.

Study Registration: This study is registered as PROSPERO CRD42019154716.

Funding: This project was funded by the National Institute for Health Research (NIHR) Evidence Synthesis programme and will be published in full in ; Vol. 25, No. 33. See the NIHR Journals Library website for further project information.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200931PMC
http://dx.doi.org/10.3310/hta25330DOI Listing

Publication Analysis

Top Keywords

myocardial infarction
20
high-sensitivity cardiac
20
cardiac troponin
20
acute myocardial
16
troponin assays
12
early rule-out
12
chest pain
12
test strategies
12
rule-out acute
8
acute chest
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!