Background: Single-position prone lateral interbody fusion is a recently introduced technical modification of the minimally invasive retroperitoneal transpsoas approach for lateral lumbar interbody fusion (LLIF). Several technical descriptions of single-position prone LLIF have been published with traditional fluoroscopy for guidance. However, there has been no investigation of either three-dimensional computed tomography-based navigation for prone LLIF or integration with robotic assistance platforms with the prone lateral technique. This study evaluated the feasibility and safety of spinal navigation and robotic assistance for single-position prone LLIF.

Methods: Retrospective review of medical records and a prospectively acquired database for a single center was performed to examine immediate and 30-day clinical and radiographic outcomes for consecutive patients undergoing single-position prone LLIF with spinal navigation and/or robotic assistance.

Results: Nine patients were treated, 4 women and 5 men. Mean age was 65.4 years (range, 46-75 years), and body mass index was 30.2 kg/m (range, 24-38 kg/m). The most common surgical indication was adjacent segment disease (44.4%), followed by pseudarthrosis (22.2%), spondylolisthesis (11.1%), degenerative disc disease (11.1%), and recurrent stenosis (11.1%). Postoperative approach-related complications included pain-limited bilateral hip flexor weakness (4/5) and pain-limited left knee extension weakness (4/5) in 1 patient (11.1%) and right lateral thigh numbness and dysesthesia in 1 patient (11.1%). All cages were placed within quarters 2-3, signifying the middle portion of the disc space. There were no instances of misguidance by navigation.

Conclusions: Integration of spinal navigation and robotic assistance appears feasible, accurate, and safe as an alternative to fluoroscopic guidance for single-position LLIF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2021.05.097DOI Listing

Publication Analysis

Top Keywords

single-position prone
20
prone lateral
12
interbody fusion
12
prone llif
12
robotic assistance
12
spinal navigation
12
lateral lumbar
8
lumbar interbody
8
feasibility safety
8
navigation robotic
8

Similar Publications

Prone Lateral Transpsoas Approach to the Spine: A Technical Guide for Mastery.

Int J Spine Surg

January 2025

Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA

Background: The single-position prone transpsoas (PTP) lateral interbody fusion represents an alternative approach to the traditional lateral lumbar interbody fusion (LLIF) typically performed with the patient in the lateral decubitus position. Advantages of PTP surgery include improved segmental lordosis, single-position surgery, and ease of performing posterior techniques as needed. However, the learning curve of PTP is distinct from that of traditional LLIF surgery performed with the patient in the lateral decubitus position.

View Article and Find Full Text PDF

Fully Navigated Single-Position Prone Lateral Lumbar Interbody Fusion: A Detailed Technical Report and Description of 15 Cases.

Int J Spine Surg

December 2024

Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland

Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.

View Article and Find Full Text PDF

Background: Recent studies highlight the increasing adoption of single-position prone lateral(SP-PL) and single-position lateral decubitus(SP-LD) in Minimally Invasive Spine Surgery(MISS) to reduce operative time, enhance patient safety, and improve surgical accessibility.

Objective: To assess the differences between SP-PL and SP-LD achievement of optimal postoperative outcomes and post-operative complication rates.

Study Design: Retrospective review of prospectively collected MIS database.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted to evaluate the safety and effectiveness of lateral lumbar interbody fusion (LLIF) performed with patients in a prone position, comparing it to the traditional lateral position.
  • The study included 20 patients who underwent LLIF while prone, with findings showing no intraoperative complications, but some patients experienced transient weakness and other postoperative issues.
  • Overall, patient-reported outcomes improved significantly after the procedure, and while there were some complications in the prone group, they were not statistically different from those in the lateral group.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!