Introduction: Deep brain stimulation (DBS) therapy for Parkinson's Disease (PD) and dystonia is associated with the possibility of both minor and major complications. One possible side effect is the depletion of implantable pulse generator (IPG) battery and the associated sudden recurrence of PD or dystonia symptoms, which can be potentially life-threatening. Delayed or postponed outpatient visits due to COVID -19 may be a risk factor of battery end-of-life consequences.
Objective: To analyse the clinical outcomes in reported PD and dystonia patients treated with DBS, who, as a result of the sudden depletion of the neurostimulator battery, developed life-threatening symptoms.
Materials And Methods: The databases of PubMed, Scopus, EMBASE and Google Scholar were searched using pre-established criteria.
Results: A total of 244 articles was found, of which 12 met the adopted criteria. Selected papers presented a total of 17 case reports of DBS-treated patients - 11 with PD, and six with dystonia - who had depleted IPG batteries and due to rapid worsening of PD/dystonia symptoms required urgent hospital admission. IPG battery replacement was the only effective treatment in the majority of cases.
Conclusions: IPG battery depletion can result in fatal outcomes. Sudden recurrence of PD or dystonia symptoms in patients treated by DBS can be potentially life-threatening, so scheduling the replacement of a discharged IPG battery should not be postponed. The COVID-19 pandemic should alert staff at emergency, neurology and movement disorders wards not to postpone the visits of patients with an implanted DBS system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5603/PJNNS.a2021.0041 | DOI Listing |
Pain Physician
November 2024
Makous Research, LLC, Carlsbad, CA.
Pain Pract
January 2025
Department of Anesthesiology and Pain Medicine, Haeundae Paik Hospital, Inje University, Busan, South Korea.
Introduction: This case report presents an instance of an S-Series™ slim paddle lead fracturing during extraction, highlighting potential risks associated with the removal of this lead.
Case Report: A 47-year-old male with complex regional pain syndrome type 2, unresponsive to pharmacotherapy, had undergone the implantation of two spinal cord stimulator (SCS) leads, an Octrode™ cylindrical and an S-series™ slim paddle, using the Epiducer™ system (St Jude Medical) 9 years earlier, with a subsequent intrathecal baclofen pump installed 1 year after SCS. Initially, these interventions stabilized the patient's pain symptoms.
Pain Manag
October 2024
Chronic Interventional Pain Medicine department of Anesthesiology, Emory University, Atlanta, GA, 30322, USA.
As spinal cord stimulation (SCS) becomes a staple of chronic pain management, the SCS industry must constantly evolve to ensure safety, convenience and enhanced efficacy. Beyond waveforms and size, MR-conditionality is a key differentiator sought out by physicians and patients when choosing SCS devices. Many common SCS complications, including lead migration, can affect the MR-conditionality.
View Article and Find Full Text PDFJ Pain Res
September 2024
Pain Management, International Spine Pain & Performance Center, Washington, DC, USA.
J Phys Chem B
April 2024
Materials Science Group, Indira Gandhi Centre for Atomic Research, a CI of Homi Bhabha National Institute (Mumbai), Kalpakkam, TN 603102, India.
Iron phosphate glasses (IPGs) have been proposed as futuristic materials for nuclear waste immobilization and anode materials for lithium batteries. Recently, many attempts have been made to propose atomistic models of IPGs to explain their properties from an atomistic viewpoint. In this paper, we seek to produce small scale models of IPG that can be handled within the scheme of density functional theory (DFT) to study its electronic structure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!