Introduction: Acute liver failure (ALF) is a rare disease that may lead to cerebral edema and death. An increased optic nerve sheath diameter (ONSD) may reflect an early increase in intracranial pressure. We assessed the feasibility and safety of the ONSD measurement and its association with outcomes in patients with ALF.

Methods: This was an open-label prospective cohort study including adult patients with ALF admitted to a liver-specialized intensive care unit (ICU) in an academic center between October 2018 and February 2020 (among 24): 20 as intention-to-treat and 17 as per-protocol analyses. The ONSD measurement (primary exposure) used an ultrasound transducer (3 determinations on each eye per patient). The primary outcome was hospital mortality.

Results: Among the 20 patients, 11 (55.0%) were females and the mean age was 45 ± 16 years. On the day of ONSD measurement (median 32.4 h post-ICU admission; IQR 19.8-59.8): 8 patients (40.0%) were in a coma, the mean international normalized ratio (INR) was 3.3 ± 1.4, median bilirubin was 12.3 mg/dL (IQR 4.7-24.5), mean ammonia was 163 ± 101 µmol/L, and mean SOFA score was 11 ± 5. The mean bilateral ONSD was 5.6 ± 0.7 mm, with a very good correlation between right and left eyes (Pearson's = 0.90). Ten (50.0%) patients were transplanted and 13 (65.0%) patients survived the hospital stay (all with a 2-month extended Glasgow Outcome Scale of 8). The mean ONSD was significantly higher for hospital non-survivors than survivors both in the intention-to-treat (6.2 vs. 5.3 mm; = 0.004) and per-protocol (6.2 vs. 5.2 mm; = 0.004) analyses. No adverse effects from ONSD measurements were reported.

Conclusions: In patients with ALF, a higher ONSD was associated with higher hospital mortality. ONSD measurement is feasible and safe and may have prognostic value.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8138150PMC
http://dx.doi.org/10.1159/000511646DOI Listing

Publication Analysis

Top Keywords

onsd measurement
16
onsd
9
optic nerve
8
nerve sheath
8
sheath diameter
8
acute liver
8
liver failure
8
prospective cohort
8
cohort study
8
patients alf
8

Similar Publications

Background: Optic nerve sheath diameter (ONSD) is a promising noninvasive parameter for intracranial pressure (ICP) assessment. However, in the setting of aneurysmal subarachnoid hemorrhage (aSAH), several previous studies have reported no association between ultrasonically measured ONSD and ICP. In this study, we evaluate ONSD in patients with aSAH using a novel method of automated real-time ultrasonographic measurements and explore whether factors such as having undergone surgery affects its association to ICP.

View Article and Find Full Text PDF

Neuro-ophthalmological changes have been reported after prolonged exposure to microgravity; however, the pathophysiology remains unclear. Furthermore, several countermeasures have been suggested to counteract the side effects of microgravity. The objectives of the present study were twofold: (1) to assess the neuro-ophthalmological impact of 60 days of head-down bed rest (HDBR) and (2) to determine the potential effects of an antioxidant cocktail.

View Article and Find Full Text PDF

Objectives: While lumbar puncture (LP) remains gold standard for assessing intracranial pressure (ICP), LP can be difficult to perform and lead to complications. Noninvasive correlations for elevated ICP via ocular ultrasound (OUS) have shown mixed results. The primary objective of this study is to identify the frequency and test characteristics of the crescent sign on OUS for elevated ICP.

View Article and Find Full Text PDF

Evaluation and management of neurological complications in acute liver failure.

Best Pract Res Clin Gastroenterol

December 2024

Institute of Digestive & Liver Diseases, BLK Superspeciality Hospital, Delhi, India. Electronic address:

Neurological complications in acute liver failure are the most common cause of mortality in this group of patients. Almost all neurologic complications arise from underlying increase in intracranial pressure in ALF. In addition to symptomatic management, the treatment relies on measures to bring down ICP.

View Article and Find Full Text PDF

Aim: This study assessed the effectiveness of ultrasonography-measured optic nerve sheath diameter (ONSD) in predicting large vessel occlusion (LVO) in ischemic stroke patients.

Materials And Methods: This single-center, prospective observational study involved patients presenting to the emergency department within 24 hours of symptom onset with moderate to severe stroke, and healthy volunteers.

Results: The study included 133 ischemic stroke patients and 63 healthy volunteers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!