Thermal Safety of Endoscopic Usage in Robot-Assisted Middle Ear Surgery: An Experimental Study.

Front Surg

Department of Otolaryngology-Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Published: May 2021

The widespread application of endoscopic ear surgery (EES), performed through the external auditory canal, has revealed the limitations of the one-handed technique. The RobOtol® (Collin ORL, Bagneux, France) otological robotic system has been introduced to enable two-handed procedures; however, the thermal properties of dedicated endoscopes, which are usually used in neurosurgery, called "neuro-endoscopes," have not yet been clarified for the robotic systems. In this study, we aimed to profile the thermal characteristics of two dedicated neuro-endoscopes, as compared to endoscopes used routinely in manual EES, called "oto-endoscopes," and defined by a smaller diameter and shorter length, and to discuss the safe application of robotic assistance in EES. Two neuro-endoscopes (3.3 mm, 25 cm, 0°/30°) were studied using two routine light sources (LED/xenon), and two routine oto-endoscopes (3 mm, 14 cm, 0°/30°) were initially measured to provide a comprehensive comparison. Light intensities and temperatures were measured at different power settings. The thermal distributions were measured in an open environment and a human temporal bone model of EES. The cooling measures were also studied. Light intensity was correlated with stabilized tip temperatures ( < 0.01, = 0.8719). Under 100% xenon power, the stabilized temperatures at the tips of 0°, 30° neuro-endoscopes, and 0°, 30° oto-endoscopes were 96.1, 60.1, 67.8, and 56.4°C, respectively. With 100% LED power, the temperatures decreased by about 10°C, respectively. For the 0° neuro-endoscope, the illuminated area far away 1cm from the tip was below 37°C when using more than 50% both power, while this distance for 30° neuro-endoscope was 0.5 cm. In the EES temporal bone model, the round window area could reach 59.3°C with the 0° neuro-endoscope under 100% xenon power. Suction resulted in a ~1-2°C temperature drop, while a 10 mL saline rinse gave a baseline temperature which lasted for 2.5 min. Neuro-endoscope causes higher thermal releasing in the surgical cavity of ESS, which should be especially cautious in the robotic system usage. Applying submaximal light intensity, a LED source and intermittent rinsing should be considered for the safer robot-assisted EES using a neuro-endoscope that allows a two-handed surgical procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160440PMC
http://dx.doi.org/10.3389/fsurg.2021.659688DOI Listing

Publication Analysis

Top Keywords

ear surgery
8
robotic system
8
temporal bone
8
bone model
8
light intensity
8
stabilized temperatures
8
100% xenon
8
xenon power
8
0° 30°
8
0° neuro-endoscope
8

Similar Publications

Influence of the wet-ear state on the outcomes of tympanic membrane repair under ear endoscopy: a prospective case-control study.

BMC Surg

January 2025

Department of Otolaryngology-Head and Neck Surgery, Zhangqiu People's Hospital, No.1920 Mingshui Huiquan Road, Zhangqiu Distict, Jinan, 250200, People's Republic of China.

Background: To prospectively determine whether tympanoplasty for tympanic membrane perforation (TMP) in wet ears impacts recovery.

Methods: We prospectively enrolled 32 TMP patients (2021-2023) and divided them into the wet-ear (14 patients) and dry-ear groups (18 patients), according to the presence of middle-ear secretions/edema. All patients underwent high-resolution thin-slice computed tomography, ear endoscopy, and pure tone audiometry.

View Article and Find Full Text PDF

Vangl is a planar cell polarity (PCP) core protein essential for aligned cell orientation along the epithelial plane perpendicular to the apical-basal direction, which is important for tissue morphogenesis, development and collective cell behavior. Mutations in Vangl are associated with developmental defects, including neural tube defects (NTDs), according to human cohort studies of sporadic and familial cases. The complex mechanisms underlying Vangl-mediated PCP signaling or Vangl-associated human congenital diseases have been hampered by the lack of molecular characterizations of Vangl.

View Article and Find Full Text PDF

Twenty years of experience with lesions involving the temporomandibular joint and adjacent structures complex.

Int J Oral Maxillofac Surg

January 2025

Department of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China; Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China; National Clinical Research Center of Stomatology, Shanghai, China. Electronic address:

With their close anatomical relationship, the temporomandibular joint (TMJ), mandibular ramus, skull base, ear, and infratemporal fossa make up a complex structure that may collectively be referred to as the 'TMJ and adjacent structures complex' (TASC). This study presents the neoplasms that may be encountered in the TASC region and their classification, which may be useful for the surgical treatment. Data of 1022 consecutive patients treated with resection of TASC neoplasms from May 2000 to October 2022 were reviewed.

View Article and Find Full Text PDF

Objectives: To assess the prevalence and associated factors of hearing loss in Ethiopia, considering socioeconomic conditions, regional variations and age-related impacts.

Design: Nationwide cross-sectional survey.

Setting: Data were collected from 2 February to 10 June 2023, covering all regions of Ethiopia except Tigray (due to security concerns).

View Article and Find Full Text PDF

Experts' discussion: implications of the World Health Organization's World report on hearing for the cochlear implant field.

Braz J Otorhinolaryngol

January 2025

World Health Organization, Department of Noncommunicable Diseases, Rehabilitation and Disability, Disability and Rehabilitation Unit, Geneva, Switzerland.

Objective: This review aims to analyse the implications of the World Health Organization's 2021 world report on hearing, with a particular focus on the cochlear implant field. The objective is to understand the challenges and opportunities highlighted in the report and propose viable solutions for effective implementation within the cochlear implant community.

Methods: Following the release of the World Health Organization's world report on hearing, cochlear implant professionals explored and discussed the implications of the report with examples from various countries to understand the disparities in access, reimbursement policies, and social stigma associated with hearing loss.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!