Aims: Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment.

Methods: A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.

Results: Mean overall patient satisfaction for the entire cohort was 4.7 (SE 0.1) on a 5-point Likert scale, with 93% being either very satisfied or satisfied compared with a Likert of 4.3 and patient satisfaction of 81% in the mechanical alignment group (p < 0.001 and p < 0.006 respectively). At mean follow-up of 17 months (11 to 27), the mean overall Likert, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten Joint Score, and Knee Society Knee and Function Scores were significantly better in the kinematic group than in the neutral mechanical alignment group. The most common complication in both groups was contracture requiring manipulation under anaesthesia, involving seven knees (6.1%) in the kinematic group and nine knees (7.8%) in the mechanical alignment group.

Conclusion: With the advent of advanced technology, and the ability to obtain accurate bone cuts, the target limb alignment, and soft-tissue balance within millimetres, using a restricted kinematic alignment concept demonstrated excellent patient satisfaction following primary TKA. Longer-term analysis is required as to the durability of this method. Cite this article:  2021;103-B(6 Supple A):59-66.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.103B6.BJJ-2020-2357.R1DOI Listing

Publication Analysis

Top Keywords

patient satisfaction
20
restricted kinematic
20
mechanical alignment
16
kinematic alignment
12
varus deformity
12
alignment
9
total knee
8
knee arthroplasty
8
kinematic
8
tka concept
8

Similar Publications

Background: Patient provider interactions influence patient treatment adherence, clinical outcomes, patient satisfaction, and an overall patient's engagement in healthcare decisions. The purpose of this study was to examine the effectiveness of patient provider educational interactions and associated variables on patient reported outcomes in the hip dysplasia population.

Methods: A secondary data analysis was completed with 6-month postoperative survey data from participants, who had undergone periacetabular osteotomy.

View Article and Find Full Text PDF

Introduction: Individuals with esophageal and gastroesophageal junction (GEJ) cancers are at especially high risk of malnutrition. However, most patients with malnutrition do not receive adequate nutritional support. We conducted a single-arm trial to test the implementation of Support Through Remote Observation and Nutrition Guidance (STRONG), a multilevel digital intervention to improve nutritional outcomes for patients with locally advanced esophageal and gastroesophageal junction cancer.

View Article and Find Full Text PDF

Introduction: This is a double clinical trial conducted to study the patient satisfaction and comfort during and after surgical removal of impacted mandibular 3rd molar using Piezo electric tips.

Material And Methods: Two groups of 25 each [14 (56 %) males and 11 (44 %) females] and [18 (72 % males and 07 (28 %) females] represented the Rotary and Piezo groups respectively with bilateral impactions. one side of the patient is operated by piezo and the other side by rotary instrument after a gap of 2-3 week between the procedures.

View Article and Find Full Text PDF

Background: The use of virtual reality is increasing in nursing to ensure patient safety and to improve the quality of care in the education of nurses.

Aim: To develop a virtual reality software for intensive care patient care management and to investigate the effect of this software on novice intensive care nurses.

Study Design: This study protocol contains a randomized controlled experimental design research.

View Article and Find Full Text PDF

Background: Research demonstrates that Point-of-care ultrasound (POCUS) improves clinical outcomes for patients. Improving clinician satisfaction with POCUS should promote utilization into everyday practice, leading to improved clinical outcomes. Despite this benefit, there are still barriers to use including POCUS workflow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!