Aims: Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA.

Methods: A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.

Results: In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001).

Conclusion: RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article:  2021;103-B(6 Supple A):74-80.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.103B6.BJJ-2020-2003.R1DOI Listing

Publication Analysis

Top Keywords

component positioning
16
polyethylene thickness
12
limb alignment
12
robotic-assisted total
8
total knee
8
knee arthroplasty
8
accuracy precision
8
planned polyethylene
8
polyethylene insert
8
insert thickness
8

Similar Publications

Simultaneous Treatment of Pseudo-gynecomastia and Lateral Chest in Patients with Massive Weight Loss.

Aesthetic Plast Surg

January 2025

Department of Plastic, Burn and Maxillofacial Surgery, Ain Shams University, 7 Mohsen Roshdy street, Nasr City, Cairo, 11731, Egypt.

Background: Pseudogynecomastia in MWL patients is characterized by excess skin in chest, lateral chest, axilla and upper abdomen without enlargement of the breast glandular component. The aim of this work was to study long-term aesthetic outcomes of correction of severe pseudogynecomastia post-weight loss with inferior pedicle technique with some refinements.

Methodology: This prospective study included 15 patients underwent chest contouring after massive weight loss within period of 2 years between January 2022 and January 2024.

View Article and Find Full Text PDF

Cultural assumptions and the good death: rethinking global frameworks.

Med Humanit

January 2025

Brighton and Sussex Medical School, University of Sussex, Brighton, UK

The concept of a 'good death' remains debated, with research largely focused on the Global North, leaving gaps in understanding its relevance to the Global South. While the concept of a good death is not a strict binary, notable differences exist. In the Global North, emphasis often lies on individual autonomy and preferences, whereas in the Global South, the focus tends to include the perspectives and needs of family and social networks.

View Article and Find Full Text PDF

Gaussia Luciferase (GLuc) is a renowned reporter protein that can catalyze the oxidation of coelenterazine (CTZ) and emit a bright light signal. GLuc comprises two consecutive repeats that form the enzyme body and a central putative catalytic cavity. However, deleting the C-terminal repeat only limited reduces the activity (over 30% residual luminescence intensity detectable), despite being a key part of the cavity.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to investigate the relationships between a Power Leg Press test (PLP) with walking capacity and self-reported performance and participation in individuals with Cerebral Palsy (CP), and to compare the strength of the associations between two power tests (PLP and isokinetic (IsoK)) with walking capacity.

Methods: Ambulatory individuals with CP (n = 33; age 17.89 ± 7.

View Article and Find Full Text PDF

Objectives: To assess the effect of occlusion and implant number/position on stress distribution in Kennedy Class II implant-assisted removable partial denture (IARPD).

Materials And Methods: IARPDs were designed in six models: with one implant (bone level with a platform of 4 mm and length of 10 mm) at the site of (I) canine, (II) between first and second premolars, (III) first molar, (IV) second molar, or two implants at the sites of (V) canine-first molar, and (VI) canine-second molar. A conventional RPD served as control.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!