Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Toxic impurities were found in leucomycin and its preparation, however the content determination of impurities was challengeable due to the lacking of their reference standards. In this study, we developed high-performance liquid chromatography method coupled with charged aerosol detection (CAD) for the quantification of related substance of leucomycin (kitasamycin) bulk drugs and tablets, however, the CAD was not yet popular. In order to carry out quantitation work conveniently in the laboratory without CAD instruments, a high-performance liquid chromatography method coupled with ultraviolet (UV) detection was developed with the assistant of the HPLC-CAD results. The relative response of impurities on CAD chromatogram was used for guiding the establishment of HPLC-UV method, which could achieve the quantitation task in the absence of impurity reference standards. The developed HPLC-UV method was validated according to the ICH guideline and showed good precision, reproducibility and linearity with determination coefficient higher than 0.9999. The limit of detection and quantitation were 0.3 and 0.5 μg mL, respectively. The recoveries were 92.9 %-101.5 % at the spiked concentration levels of 0.1 %, 0.8 %, 1.0 and 1.2 % with relative standard deviations (RSDs, n = 3) lower than 2.0 %. Finally, the developed HPLC-CAD and -UV methods were compared by the determination of impurities in several batches of leucomycin bulk drugs and tablets. The results demonstrated that the developed HPLC-UV method was simple and reliable. This study developed methods to quantify the related substance in leucomycin and tablets, and discussed a strategy of the conversion of HPLC-CAD method to HPLC-UV method. The developed methods could be considered for implementation into pharmacopeial monographs in the future.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2021.114148 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!