Platelet-Rich Plasma in Arthroscopic Rotator Cuff Repair: Clinical and Radiological Results of a Prospective Randomized Controlled Trial Study at 10-Year Follow-Up.

Arthroscopy

Laboratory of Applied Biomechanics, Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan; U.O.C. 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan; Research Center for Adult and Pediatric Rheumatic Diseases (RECAP-RD), Department of Biomedical Sciences for Health, Università degli Studi di Milano, Milan. Electronic address:

Published: January 2022

AI Article Synopsis

  • The study aimed to compare the long-term outcomes of arthroscopic rotator cuff repair with and without platelet-rich plasma (PRP) treatment over a 10-year period.
  • A total of 38 out of 53 patients were evaluated, showing high satisfaction rates (90%) in both PRP and control groups, with good clinical results, but no significant difference between the groups.
  • Despite some patients experiencing re-ruptures, the incidence was similar in both groups, suggesting that adding PRP may not significantly impact the long-term integrity of the repaired tendon.

Article Abstract

Purpose: The aim of the study is to compare, at 10-year follow-up, the clinical and radiological outcomes of arthroscopic rotator cuff repair with or without the addition of platelet-rich plasma (PRP) over the tendon-bone interface at the end of the surgical procedure.

Methods: Of 53 patients recruited in the study, and randomly divided into 2 groups (PRP = 26; control = 27), 38 were re-evaluated at least 10 years after the index procedure. The clinical evaluation was carried out through: University of California at Los Angeles (UCLA) Shoulder Score, Visual Analogue Scale (VAS), Simple Shoulder Test, Constant-Murley Score (CMS), Single Assessment Numerical Evaluation (SANE), American Shoulder and Elbow Surgeons (ASES) and isometric strength in abduction, forward flexion and external rotation. Musculoskeletal ultrasonography had been used to evaluate the integrity of the repaired cuff.

Results: A number of 38 (71%) patients (PRP = 17; control = 21) with a median age of 71 [64.75-76.50] years have been evaluated. Satisfaction at follow-up is high (90%), without statistically significant difference between the two groups. We report good and excellent clinical results in both groups (PRP vs control): CMS (81.62 [72.47-85.75] vs 77.97 [69.52-82.55] points), UCLA (34 [29.00-35.00] vs 33 [29.00-35.00] points), VAS (0.34 [0.00-1.85] vs 0.70 [0.00-2.45] cm). It was not possible to find a statistically significant difference for the variables analyzed, except for ASES and SANE. On average, 37% of the operated patients had a re-rupture at the ultrasound examination, regardless of the treatment group (P = 1.00). Compared with the previous radiological control at the 2-year follow-up, new retears occurred in 6% of the patients who received PRP treatment, whereas in the control group the percentage raises to 14% (P = .61).

Conclusion: The clinical and radiological outcomes at the 10-year follow-up show a substantial uniformity of results between the 2 groups. The minor differences that had been observed at 2-year follow-up disappeared at long term. Patients' satisfaction is still high 10 years after surgical treatment.

Level Of Evidence: Level II, randomized controlled trial, treatment study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2021.05.017DOI Listing

Publication Analysis

Top Keywords

clinical radiological
12
10-year follow-up
12
platelet-rich plasma
8
arthroscopic rotator
8
rotator cuff
8
cuff repair
8
randomized controlled
8
controlled trial
8
radiological outcomes
8
prp = control =
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!