Background: The aim of the study was to derive and compare metabolic parameters relating to benign and malignant pulmonary nodules using dynamic 2-deoxy-2-[fluorine-18]fluoro-D-glucose (F-FDG) PET/CT, and nodule perfusion parameters derived through perfusion computed tomography (CT).

Patients And Methods: Twenty patients with 21 pulmonary nodules incidentally detected on CT underwent a dynamic F-FDG PET/CT and a perfusion CT. The maximum standardized uptake value (SUV) was measured on conventional F-FDG PET/CT images. The influx constant ( ) was calculated from the dynamic F-FDG PET/CT data using Patlak model. Arterial flow (AF) using the maximum slope model and blood volume (BV) using the Patlak plot method for each nodule were calculated from the perfusion CT data. All nodules were characterized as malignant or benign based on histopathology or 2 year follow up CT. All parameters were statistically compared between the two groups using the nonparametric Mann-Whitney test.

Results: Twelve malignant and 9 benign lung nodules were analysed (median size 20.1 mm, 9-29 mm) in 21 patients (male/female = 11/9; mean age ± SD: 65.3 ± 7.4; age range: 50-76 years). The average SUV values ± SD of the benign and malignant nodules were 2.2 ± 1.7 . 7.0 ± 4.5, respectively (p = 0.0148). Average values in benign and malignant nodules were 0.0057 ± 0.0071 and 0.0230 ± 0.0155 min, respectively (p = 0.0311). Average BV for the benign and malignant nodules were 11.6857 ± 6.7347 and 28.3400 ± 15.9672 ml/100 ml, respectively (p = 0.0250). Average AF for the benign and malignant nodules were 74.4571 ± 89.0321 and 89.200 ± 49.8883 ml/100g/min, respectively (p = 0.1613).

Conclusions: Dynamic F-FDG PET/CT and perfusion CT derived blood volume had similar capability to differentiate benign from malignant lung nodules.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366734PMC
http://dx.doi.org/10.2478/raon-2021-0024DOI Listing

Publication Analysis

Top Keywords

benign malignant
28
f-fdg pet/ct
24
malignant nodules
16
pet/ct perfusion
12
dynamic f-fdg
12
benign
9
malignant
9
nodules
9
differentiate benign
8
malignant pulmonary
8

Similar Publications

Objective: This study explored the value of stomach ultrasound reporting and data system (Su-RADS) and two-dimensional shear wave elastography (2D-SWE) in the diagnosis of benign and malignant lesions of the gastric wall, evaluating the feasibility of combining the two methods for the diagnosis of gastric wall lesions.

Methods: 113 patients with gastric wall lesions were examined after oral gastric ultrasound contrast agent, and the grades of the gastric wall lesions were classified according to Su-RADS. Moreover, 2D-SWE was performed to measure the E value of the lesions.

View Article and Find Full Text PDF

Three-dimensional digital model of the facial nerve assisted in the excision of benign parotid tumors based on 3D-DESS-WE-MRI.

Sci Rep

December 2024

Department of Stomatology, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Henan University People's Hospital, #7 Wei Wu Road, Zhengzhou, 450003, Henan, China.

This study proposes a novel surgical technique for the excision of benign parotid tumors, utilizing a extracapsular dissection guided by a three dimensional digital model of the facial nerve(3DFN-ECD) and compares its clinical efficacy with the extracapsular dissection (ECD) method. This prospective study included 68 patients with benign parotid tumors. The control group (40 patients) received the ECD treatment, while the experimental group (28 patients), underwent the 3DFN-ECD approach proposed in this study.

View Article and Find Full Text PDF

Development of an accurate breast cancer detection classifier based on platelet RNA.

Sci Rep

December 2024

School of Medicine, The First Affiliated Hospital of Xiamen University, Xiamen University, Xiamen, Fujian, China.

Platelets possess cancer-induced reprogramming properties, thereby contributing to RNA profile alterations and further cancer progression, while the former is considered a promising biosource for cancer detection. Hence, tumor-educated platelets (TEP) are considered a prospective novel method for early breast cancer (BC) screening. Our study integrated the data from 276 patients with untreated BC, 95 with benign disease controls, 214 healthy controls, and 2 who underwent mastectomy in Chinese and European cohorts to develop a 10-biomarker diagnostic model.

View Article and Find Full Text PDF

Biliary and pancreatic tract stenosis are hallmark symptoms in pancreaticobiliary diseases, transcending malignancy. Endoscopic techniques are pivotal for biliary/pancreatic drainage; however, challenging scenarios arise when attempting to pass a guidewire (GW) through obstruction. Cholangioscopy-assisted GW placement has proven valuable, but challenges persist in its execution, particularly in maneuvering the GW through cholangioscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!