Coronary stents are deployed to treat the coronary artery disease (CAD) by reopening stenotic regions in arteries to restore blood flow, but the risk of the in-stent restenosis (ISR) is high after stent implantation. One of the reasons is that stent implantation induces changes in local hemodynamic environment, so it is of vital importance to study the blood flow in stented arteries. Based on regarding the red blood cell (RBC) as a rigid solid particle and regarding the blood (including RBCs and plasma) as particle suspensions, a non-Newtonian particle suspensions model is proposed to simulate the realistic blood flow in this work. It considers the blood's flow pattern and non-Newtonian characteristic, the blood cell-cell interactions, and the additional effects owing to the bi-concave shape and rotation of the RBC. Then, it is compared with other four common hemodynamic models (Newtonian single-phase flow model, Newtonian Eulerian two-phase flow model, non-Newtonian single-phase flow model, non-Newtonian Eulerian two-phase flow model), and the comparison results indicate that the models with the non-Newtonian characteristic are more suitable to describe the realistic blood flow. Afterwards, based on the non-Newtonian particle suspensions model, the local hemodynamic environment in stented arteries is investigated. The result shows that the stent strut protrusion into the flow stream would be likely to produce the flow stagnation zone. And the stent implantation can make the pressure gradient distribution uneven. Besides, the wall shear stress (WSS) of the region adjacent to every stent strut is lower than 0.5 Pa, and along the flow direction, the low-WSS zone near the strut behind is larger than that near the front strut. What's more, in the regions near the struts in the proximal of the stent, the RBC particle stagnation zone is easy to be formed, and the erosion and deposition of RBCs are prone to occur. These hemodynamic analyses illustrate that the risk of ISR is high in the regions adjacent to the struts in the proximal and the distal ends of the stent when compared with struts in other positions of the stent. So the research can provide a suggestion on the stent design, which indicates that the strut structure in these positions of a stent should be optimized further.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184899 | PMC |
http://dx.doi.org/10.1007/s10867-021-09571-y | DOI Listing |
J Int Med Res
January 2025
Department of Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea.
The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Current limitations in implant design often lead to trade-offs between minimally invasive surgery and achieving the desired post-implantation functionality. Here, we present an artificial intelligence inverse design paradigm for creating deployable implants as planar and tubular thermal mechanical metamaterials (thermo-metamaterials). These thermo-metamaterial implants exhibit tunable mechanical properties and volume change in response to temperature changes, enabling minimally invasive and personalized surgery.
View Article and Find Full Text PDFA A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFInt J Cardiol
December 2024
Cardiothoracic and Vascular Department (DICATOV), IRCCS Ospedale Policlinico San Martino, Genova, Italy.
Background: The results of randomized clinical trials comparing the outcomes of different strategies for driving PCI are mixed, and it remains unclear which technique for driving PCI offers the greatest benefit. The aim of the study was to compare the clinical efficacy of different techniques to guide percutaneous coronary intervention (PCI).
Methods: We search major electronic databases for randomized clinical trials evaluating clinical outcomes of PCI with stent implantation guided by coronary angiography (CA), fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), intravascular ultrasound (IVUS) and optical coherence tomography (OCT).
Rev Cardiovasc Med
December 2024
Department of Emergency, People's Hospital of Dali Bai Autonomous Prefecture, 671000 Dali, Yunnan, China.
Coronary atherosclerosis (or coronary heart disease [CHD]) is a common cardiovascular disease that seriously damages human health. Percutaneous coronary stent implantation represents the primary treatment option for severe CHD in clinical practice; meanwhile, dual antiplatelet therapy (DAPT) is widely used to reduce the risk of postoperative thrombosis. Although the mechanisms of action of the two most commonly used antiplatelet drugs, aspirin and clopidogrel, remain unclear, clinical studies have shown that some patients are susceptible to stent thrombosis-antiplatelet resistance (high on-treatment platelet reactivity [HTPR])-despite using these drugs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!