Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). The goal is to generate dose calibration curves over an extended dose range from 0 to 50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating the uncertainties in dose estimation associated with the calibration curves.

Methods: Samples of RCF (EBT3) were irradiated at a broad dose range of 0.03-50 Gy using an Elekta Synergy clinical linear accelerator. Raman spectra were acquired with a custom-built Raman micro-spectroscopy setup involving a 500 mW, multimode 785 nm laser focused to a lateral spot diameter of 30 µm on the RCF. The depth of focus of 34 µm enabled the concurrent collection of Raman spectra from the RCF active layer and the polyester laminate. The preprocessed Raman spectra were normalized to the intensity of the 1614 cm Raman peak from the polyester laminate that was unaltered by radiation. The mean intensities and the corresponding standard deviation of the active layer Raman peaks at 696, 1445, and 2060 cm were determined for the 150 × 100 µm scan area per dose value. This was used to generate three calibration curves that enabled the conversion of the measured Raman intensity to dose values. The experimental, fitting, and total dose uncertainty was determined across the entire dose range for the dosimetry system of Raman micro-spectroscopy and RCF.

Results: In contrast to previous work that investigated the Raman response of RCFs using different methods, high resolution in the dose response of the RCF, even down to 0.03 Gy, was obtained in this study. The dynamic range of the calibration curves based on all three Raman peaks in the RCF extended up to 50 Gy with no saturation. At a spatial resolution of 30 × 30 µm , the total uncertainty in estimating dose in the 0.5-50 Gy dose range was [6-9]% for all three Raman calibration curves. This consisted of the experimental uncertainty of [5-8]%, and the fitting uncertainty of [2.5-4.5]%. The main contribution to the experimental uncertainty was determined to be from the scan area inhomogeneity which can be readily reduced in future experiments. The fitting uncertainty could be reduced by performing Raman measurements on RCF samples at further intermediate dose values in the high and low dose range.

Conclusions: The high spatial resolution experimental dosimetry technique based on Raman micro-spectroscopy and RCF presented here, could become potentially useful for applications in microdosimetry to produce meaningful dose estimates in cellular targets, as well as for applications based on small field dosimetry that involve high dose gradients.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.15000DOI Listing

Publication Analysis

Top Keywords

high spatial
8
spatial resolution
8
resolution dosimetry
8
raman micro-spectroscopy
8
dosimetry uncertainty
4
uncertainty analysis
4
analysis raman
4
micro-spectroscopy readout
4
readout radiochromic
4
radiochromic films
4

Similar Publications

Background: Practice guidelines recommend patient management based on scientific evidence. Quality indicators gauge adherence to such recommendations and assess health care quality. They are usually defined as adverse event rates, which may not fully capture guideline adherence over time.

View Article and Find Full Text PDF

West Nile virus (WNV) is a mosquito-borne zoonotic flavivirus which often causes asymptomatic infection in humans but may develop into a deadly neuroinvasive disease. In this study, we aimed to investigate variables potentially associated with human WNV infection using human and mosquito WNV surveillance and monitoring datasets, established over 20 years, from 2003 to 2022, across the province of Ontario, Canada. We combined climatic and geographic data, mosquito surveillance data (n = 3010 sites), blood donation arboviral detection testing data in the human population, and demographic and socio-economic data from Canadian population censuses.

View Article and Find Full Text PDF

An investigation of the evolutionary characteristics and internal driving mechanisms of territorial space since the reform and opening up is essential. The study will guide the orderly development and rational layout of territorial space, as well as achievement transformation and high-quality development in Shanxi Province. We used land use data from 1980 to 2020, which was divided into four periods, to examine the changes in production-living-ecological spatial pattern in Shanxi Province.

View Article and Find Full Text PDF

EEG-based emotion recognition using multi-scale dynamic CNN and gated transformer.

Sci Rep

December 2024

School of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou, 434100, Hubei, China.

Emotions play a crucial role in human thoughts, cognitive processes, and decision-making. EEG has become a widely utilized tool in emotion recognition due to its high temporal resolution, real-time monitoring capabilities, portability, and cost-effectiveness. In this paper, we propose a novel end-to-end emotion recognition method from EEG signals, called MSDCGTNet, which is based on the Multi-Scale Dynamic 1D CNN and the Gated Transformer.

View Article and Find Full Text PDF

Understanding the association between urban noise and nighttime light in China.

Sci Rep

December 2024

School of Architecture and Urban-Rural Planning, Fuzhou University, Fuzhou, 350108, China.

Nighttime light data partially reflects the process of urban modernization and its reaction to urban scale, but its correlation with noise remains unclear, especially over a long-term time series, remains unclear. To address this gap, we examine 31 provincial capital cities and municipalities in China as the study area, utilizing noise monitoring data and nighttime light data to explore their relationship in urban areas from 2012 to 2021. The results show that: (1) During the study period, the regional environmental noise and night light index of 31 major cities exhibited a consistent upward trend, with the average equivalent sound level of environmental noise in most urban areas fluctuating between 50.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!