Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Comparison of two hexapod frame systems in paediatric tibial deformity correction; the Taylor Spatial Frame (TSF) and Orthex Hexapod System.
Methods: Paediatric patients with congenital and acquired tibial deformities treated with either TSF (between 2014 and 2016) or Orthex (between 2017 and 2019) frames were included in a retrospective comparative study. Outcome measures were healing index, pin infection rate, regenerate quality and density, software residual rate, deformity correction accuracy, strut exchanges and quality of life (QoL).
Results: The TSF group had 17 patients (18 frames) and the Orthex group had 21 patients (25 frames). The most common indications for tibial deformity correction were fibular hemimelia (14) and septic or traumatic growth arrest (8). The median time in frame was 230 days (TSF) 203 days (Orthex) (p= 0.06). The mean lengthening achieved was 54 mm (TSF) and 51 mm (Orthex) (p = 0.41). The healing index was 41 days/cm (TSF) 43 days/cm (Orthex) (p = 0.70). Pin site infections occurred more in the TSF cohort (40%) than in the Orthex cohort (18%) (p < 0.001). The regenerate in the Orthex group showed higher density at three months (p = 0.029) and was more homogenous (p = 0.023) at six months after frame application. Strut exchanges were less frequent with the Orthex system (p < 0.0001). QoL measures were similar in both cohorts (p = 0.92).
Conclusions: This is the first study to compare two hexapod designs in paediatric orthopaedics. The Orthex system showed superiority in regenerate quality and a significant reduction in pin site infection rates. Both systems delivered predictable and accurate limb deformity correction.
Level Of Evidence: III.