A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Use of Skin Staples as Fiducial Markers to Confirm Intraoperative Spinal Navigation Registration and Accuracy. | LitMetric

Background: With the advent of intraoperative computed tomography (CT) for image guidance, numerous examples of accurate navigation being applied to cranial and spinal pathology have come to light. For spinal disorders, the utilization of image guidance for the placement of percutaneous spinal instrumentation, complex osteotomies, and minimally invasive approaches are frequently utilized in trauma, degenerative, and oncological pathologies. The use of intraoperative CT for navigation, however, requires a low target registration error that must be verified throughout the procedure to confirm the accuracy of image guidance.

Objective: To present the use of skin staples as a sterile, economical fiducial marker for minimally invasive spinal procedures requiring intraoperative CT navigation.

Methods: Staples are applied to the skin prior to obtaining the registration CT scan and maintained throughout the remainder of the surgery to facilitate confirmation of image guidance accuracy.

Results: This low-cost, simple, sterile approach provides surface landmarks that allow reliable verification of navigation accuracy during percutaneous spinal procedures using intraoperative CT scan image guidance.

Conclusion: The utilization of staples as a fiducial marker represents an economical and easily adaptable technique for ensuring accuracy of image guidance with intraoperative CT navigation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ons/opab132DOI Listing

Publication Analysis

Top Keywords

image guidance
16
skin staples
8
staples fiducial
8
percutaneous spinal
8
minimally invasive
8
intraoperative navigation
8
accuracy image
8
fiducial marker
8
spinal procedures
8
intraoperative
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!