Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare radiation doses used for pediatric computed tomography (CT) scans at community-based referring facilities (RF) to those at a designated pediatric trauma center (PTC) to assess the consistency of radiation exposure.
Methods: In this retrospective study, patients 0 to 18 years of age with CT imaging performed either at a RF or at a PTC from January 1, 2015, to January 5, 2016, were identified. Data about patients, CT radiation dose, and characteristics of the RFs were compared.
Results: We identified 502 patients (156 RF, 346 PTC) with 281 head CTs (79 RF, 202 PTC) and 86 abdominal/pelvis CTs (28 RF, 58 PTC). The radiation dose (measured in mean dose-length product [DLP] ± 1 standard deviation) was significantly higher for RF scans compared with PTC scans (head, RF DLP = 545 ± 334 vs PTC DLP = 438 ± 186 (P < 0.001); abdomen/pelvis, RF DLP = 279 ± 160 vs PTC DLP = 181 ± 201 [P = 0.027]). There was a nonsignificant trend toward lower head CT radiation dosages at RFs with a dedicated pediatric emergency department compared with RFs without a pediatric emergency department.
Conclusions: Our data suggest that CT scans performed at RFs expose pediatric patients to significantly higher doses of radiation when compared with a PTC. These data support further study to identify factors associated with increased radiation and educational outreach to RFs.