Objective: To summarize the evidence comparing various balanced crystalloid solutions.

Data Sources: We searched MEDLINE, EMBASE, PUBMED, and CENTRAL databases.

Study Selection: We included randomized controlled trials that directly compared the IV administration of one balanced crystalloid solution with another.

Data Extraction And Analysis: We examined metabolic and patient-important outcomes and conducted meta-analysis using random effects model. For comparisons or outcomes with insufficient data to allow for pooling, we describe results narratively. We assessed risk of bias for individual trials using the Cochrane risk of bias tool and certainty of evidence using Grading of Recommendations, Assessment, Development and Evaluations methodology.

Data Synthesis: We included 24 randomized controlled trials comparing Plasmalyte, Ringer's Lactate, Ringerfundin, Hartmann's solution, Ringer's Bicarbonate, Sterofundin, Kabilyte, Normosol, and novel balanced solutions. Of the included studies, 16 were performed in the perioperative setting, six in the ICU, one in the emergency department, and one in healthy volunteers. Administration of Plasmalyte resulted in a lower postinfusion serum chloride concentration (mean difference, 0.83 mmol/L lower; 95% CI, 0.03-1.64 mmol/L lower, low certainty), higher postinfusion base excess (mean difference, 0.65 mmol/L higher, 95% CI, 0.25-1.05 mmol/L higher, low certainty), and lower postinfusion serum lactate levels (mean difference, 0.46 mmol/L lower; 95% CI, 0.05-0.87 mmol/L lower, low certainty) compared with administration of any other balanced crystalloid. There were no important differences in postinfusion serum pH or potassium when comparing Plasmalyte with other balanced crystalloids. Data addressing other comparisons or examining the impact of different balanced crystalloids on patient-important outcomes were sparsely reported and too heterogeneous to allow for pooling.

Conclusions: Administration of Plasmalyte results in lower serum concentrations of chloride and lactate, and higher base excess than other balanced crystalloids. The certainty of evidence is low and requires further study in large randomized controlled trials to inform the choice of balanced crystalloid in patients requiring volume replacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8133105PMC
http://dx.doi.org/10.1097/CCE.0000000000000398DOI Listing

Publication Analysis

Top Keywords

balanced crystalloid
20
randomized controlled
16
controlled trials
16
mmol/l lower
16
postinfusion serum
12
low certainty
12
balanced crystalloids
12
balanced
8
included randomized
8
compared administration
8

Similar Publications

Objective: To assess the impact of mild hypothermia on the distribution and elimination of an IV crystalloid fluid bolus in healthy anesthetized cats using volume kinetic (VK) analysis.

Methods: 10 adult cats were anesthetized and included in a prospective, randomized, cross-over study. The subjects were maintained either normothermic (38.

View Article and Find Full Text PDF

Early Albumin Administration in Veno-Arterial Extracorporeal Membrane Oxygenation.

Artif Organs

December 2024

Department of Cardiology and Angiology, Heart Center Freiburg University, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany.

Background: The clinical outcome and fluid balance of patients with veno-arterial extracorporeal membrane oxygenation (VA ECMO) or after extracorporeal cardiopulmonary resuscitation (eCPR) may be improved by addressing the high fluid demand with an early albumin administration.

Methods: In this prospective observational study, patients supported with VA ECMO or eCPR received early albumin administration (25 g/L) to prime the VA ECMO system. These patients were compared to patients who received a regimen based solely on balanced crystalloids (crystalloid group) or a regimen based on a 1:4 volume mixture of albumin (10 g/L) and balanced crystalloids (albumin group).

View Article and Find Full Text PDF

Background: Intraoperative fluid balance significantly affects patients' outcomes. Goal-directed fluid therapy (GDFT) has reduced the incidence of major postoperative complications by 20% for 30 days after open abdominal surgery. Little is known about GDFT during laparoscopic surgery.

View Article and Find Full Text PDF

Introduction: Dynamic indices of fluid responsiveness (FR) such as pulse pressure variation (PPV) and stroke volume variation (SVV) differ among hemodynamic monitors, which use proprietary algorithms, and vary even over a short period of time. We aimed to compare the baseline values, fluctuation and predictive value for FR of PPV and SVV measured by three minimally invasive monitors.

Patients And Methods: Twenty patients undergoing high-risk abdominal surgery were included and 45 fluid challenges were analysed.

View Article and Find Full Text PDF