A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The impact of transverse components on 4-strand tendon repairs. | LitMetric

The impact of transverse components on 4-strand tendon repairs.

J Hand Surg Eur Vol

Department of Hand Surgery, Affiliated Hospital of Nantong University, Jiangsu, China.

Published: October 2021

We investigated the effects of the transverse components of a tendon core suture on tensile resistance and strength of 4-strand repairs. Forty-four pig flexor tendons were repaired with one of the following four methods: double Tsuge, U-shaped, 4-strand cross and 4-strand rectangular repairs. We recorded the number of the repaired tendons that formed a 2 mm gap between the tendon ends during cyclic loading for 20 cycles, stiffness of the tendon at the 1st and 20th cycle, gap distance at the repair site and ultimate strength of the repair at the 20th cycle. When transverse components were added to the core suture, a greater number of tendons formed a 2 mm gap during cyclic loading. The stiffness gradually decreased, and the repair site's gap distance after cyclic loading increased with the presence of transverse components of the sutures. We conclude that the core suture's transverse components negatively impact the tensile resistance of 4-strand tendon repairs.

Download full-text PDF

Source
http://dx.doi.org/10.1177/17531934211018309DOI Listing

Publication Analysis

Top Keywords

transverse components
20
cyclic loading
12
4-strand tendon
8
tendon repairs
8
core suture
8
tensile resistance
8
tendons formed
8
formed 2 mm
8
2 mm gap
8
20th cycle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!