Objective: To investigate whether a combination of the low-dose (1 μg) adrenocorticotropin (ACTH) stimulation test and glucagon stimulation test (GST) could overcome the problem of equivocal results with the GST or ACTH test alone in patients with pituitary disorders.

Methods: The study included 41 adult patients with pituitary disorders and 20 healthy subjects who underwent evaluation of cortisol response to ACTH, GST, and a combination of both tests. Blood samples for cortisol measurement were obtained at baseline and 30, 60, 90, and 120 minutes after intravenous administration of ACTH 1 μg and 90, 120, 150, 180, 210, and 240 minutes after subcutaneous injection of glucagon 1 mg. The combination test was performed by injecting ACTH 1 μg at the 180-minute time point of the GST, with blood samples for cortisol measurement obtained at 210 and 240 minutes.

Results: Overall, 28 patients with normal cortisol response to both tests also had a normal cortisol response to the combination test. Ten patients with adrenal insufficiency in both tests also had adrenal insufficiency in the combination test, including a patient who had a peak cortisol value of 12.4 μg/dL (which is the cutoff value for the combination test). Two patients with adrenal insufficiency in the ACTH stimulation test and one patient with adrenal insufficiency in the GST had normal cortisol responses to the combination test.

Conclusion: By using an appropriate cutoff value, the combination test may offer additional information in patients with equivocal results in the GST and ACTH stimulation test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10118963PMC
http://dx.doi.org/10.20945/2359-3997000000266DOI Listing

Publication Analysis

Top Keywords

combination test
24
stimulation test
16
adrenal insufficiency
16
test
15
acth test
12
test glucagon
12
patients pituitary
12
acth stimulation
12
cortisol response
12
normal cortisol
12

Similar Publications

Digital Frequency Customized Relieving Sound for Chronic Subjective Tinnitus Management: Prospective Controlled Study.

J Med Internet Res

January 2025

ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Background: Tinnitus is a major health issue, but currently no tinnitus elimination treatments exist for chronic subjective tinnitus. Acoustic therapy, especially personalized acoustic therapy, plays an increasingly important role in tinnitus treatment. With the application of smartphones, personalized acoustic stimulation combined with smartphone apps will be more conducive to the individualized treatment and management of patients with tinnitus.

View Article and Find Full Text PDF

Topological indices are crucial tools for predicting the physicochemical and biological features of different drugs. They are numerical values obtained from the structure of chemical molecules. These indices, particularly the degree-based TIs are a useful tools for evaluating the connection between a compound's structure and its attributes.

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

In order to address many issues, such as the inconsistent and unreliable seeding process in traditional mechanical garlic seed metering systems (SMS), as well as the lack of ability to monitor the effectiveness of the seeding, a highly accurate electric-driven metering system (EDMS) was developed and created specifically for garlic seed planters. This study provided a description of the overall structure and functioning principle, as well as an analysis of the mechanism for smooth transit and delivery. A combination of an infrared (IR) sensor, Arduino Mega board, stepper motor, speed sensor, and a Wi-Fi module was employed to operate the EDMS, as well as monitor and count the quantity of garlic seeds during the planting process and determine the qualified rate (QR) and missing rate (MR).

View Article and Find Full Text PDF

Background: Posttraumatic stress disorder (PTSD) affects 3.9% of the general population. While massed cognitive processing therapy (CPT) has demonstrated efficacy in treating chronic PTSD, a substantial proportion of patients still continue to meet PTSD criteria after treatment, highlighting the need for novel therapeutic approaches.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!