Objectives: This study aimed to identify potential clinical and radiological predictors associated with the outcome of discectomies.

Methods: In this retrospective observational study, the material comprised preoperative CBCT images and medical records of 62 patients with disc derangement disorders, who had undergone discectomy because of disc displacement with reduction (DDwR), disc displacement without reduction (DDwoR), systemic arthritis (SA), or joint hypermobility. Clinical and radiographic variables were analysed in relation to success rate determined by subjective, objective and combined outcomes.

Results: The success odds ratio was 11 times higher in patients with painful DDwR versus that of SA (p = 0.03), and even 25.9 times higher when considering solely objective outcome (p = 0.03). In the absence of subchondral pseudocyst, there were 5.2 times higher odds to have a successful subjective outcome (p = 0.04). Extensive bone apposition on the temporal joint component indicated a 9.3 times higher likelihood of a failed objective outcome (p = 0.04).

Conclusions: There is a significant higher risk for combined outcome failure for the diagnosis SA involving the TMJ compared with DDwR. Predictors of importance based on CBCT findings related to the objective outcome failure were extensive bone apposition on the temporal joint component and condylar subchondral pseudocysts for the subjective outcome failure.

Download full-text PDF

Source
http://dx.doi.org/10.1111/odi.13923DOI Listing

Publication Analysis

Top Keywords

times higher
16
objective outcome
12
outcome failure
12
disc displacement
8
displacement reduction
8
subjective outcome
8
extensive bone
8
bone apposition
8
apposition temporal
8
temporal joint
8

Similar Publications

The contributed absorber design in graphene addition with the displacement of three materials for resonator design in Aluminum (Al), the middle substrate position with Titanium nitride (TiN), and the ground layer deposition by Iron (Fe) respectively. For the absorption validation highlight, the best four absorption wavelengths (µm) of 0.29, 0.

View Article and Find Full Text PDF

Nonthermal plasma has been extensively utilized in various biomedical fields, including surface engineering of medical implants to enhance their biocompatibility and osseointegration. To ensure robustness and cost effectiveness for commercial viability, stable and effective plasma is required, which can be achieved by reducing gas pressure in a controlled volume. Here, we explored the impact of reduced gas pressure on plasma properties, surface characteristics of plasma-treated implants, and subsequent biological outcomes.

View Article and Find Full Text PDF

Warfarin is the most widely used oral anticoagulant in clinical practice. The cytochrome P450 2C9 (CYP2C9), vitamin K epoxide reductase complex 1 (VKORC1), and cytochrome P450 4F2 (CYP4F2) genotypes are associated with warfarin dose requirements in China. Accurate genotyping is vital for obtaining reliable genotype-guided warfarin dosing information.

View Article and Find Full Text PDF

Alcohol-based fuels have shown high compatibility with spark-ignition (SI) engines, which require improvements in fuel efficiency and emissions reduction to meet modern environmental standards. While extensive research has been conducted on ethanol and other lower-order alcohols, there has been comparatively limited investigation into higher-order alcohols like butanol and pentanol as fuel alternatives. Previous studies on pentanol-gasoline blends in SI engines have demonstrated improved engine performance and reduced emissions.

View Article and Find Full Text PDF

Numerical simulation study on the influence of bend diameter rate on the flow characteristics of nature gas hydrate particles.

Sci Rep

December 2024

Jiangsu Key Laboratory of Oil-Gas Storage and Transportation Technology, Changzhou University, Changzhou, 213164, Jiangsu, China.

Bend pipe is a common part of long distance pipeline. There is very important to study the flow law of hydrate particles in the bend pipe, and pipeline design will be optimized. In addition, the efficiency and safety of pipeline gas transmission will be improved.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!