A novel in situ imaging solution and detectors array for the focused electron beam (e-beam) are the first time proposed and demonstrated. The proposed in-tool, on-wafer e-beam detectors array features full FinFET CMOS logic compatibility, compact 2Â T pixel structure, fast response, high responsivity, and wide dynamic range. The e-beam imaging pattern and detection results can be further stored in the sensing/storage node without external power supply, enabling off-line electrical reading, which can be used to rapidly provide timely feedback of the key parameters of the e-beam on the projected wafers, including dosage, accelerating energy, and intensity distributions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149521 | PMC |
http://dx.doi.org/10.1186/s11671-021-03552-9 | DOI Listing |
Rev Sci Instrum
December 2024
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 200083 Shanghai, China.
Infrared photoluminescence (PL) spectroscopy with micron-scale spatial resolution is essential for the optoelectronic characterization of narrow-gap microstructures and single defects, yet it poses significant challenges due to the exceedingly weak PL signal and strong background thermal emission. This work introduces an infrared micro-PL (μPL) mapping system that achieves a spatial resolution of ∼2 μm, leveraging the inherent advantages of the step-scan Fourier transform infrared spectrometer-based modulated PL technique in the mid- and far-infrared regions. The configuration of the experimental system is described, and a theoretical upper limit of spatial resolution is derived to be about 1.
View Article and Find Full Text PDFDrug Test Anal
December 2024
Department of Biomedical Engineering, Institute of Forensic Medicine, University of Basel, Basel, Switzerland.
Drug checking services (DCS) are entities that allow recreational drug users to have street drug samples analyzed. Diverse analytical methods are applied for DCS, ranging from test strips to mass spectrometry (MS). This work evaluates the performance and utility of common methodologies used for DCS operating with off-site drug testing, while additionally assessing the potential of gas chromatography coupled to vapor phase infrared spectroscopy (GC-IR).
View Article and Find Full Text PDFFood Sci Nutr
December 2024
Food Quality Control and Analysis Program, Ula Ali Kocman Vocational School Mugla Sitki Kocman University Ula Mugla Turkey.
The current study aims to prepare a green extract using a new method in addition to conventional extraction methods including; methanolic and ultrasonic extraction of , to compare their phenolic composition utilizing high-performance liquid chromatograph equipped with a diode array detector (HPLC-DAD), anti-bacterial, anti-oxidant, and enzyme inhibition activities. The results of HPLC-DAD analysis showed that Rosmarinic acid was found the highest amount in the methanolic extract followed by ultrasonic and green extracts as 169.7 ± 0.
View Article and Find Full Text PDFJ Sep Sci
December 2024
Natural and Medical Sciences Research Center, University of Nizwa, Nizwa City, Oman.
Micellar liquid chromatography (MLC) has proven beneficial efficiency and ecological impact for routine quality control activities. In the proposed study, cyrene was investigated for the first time, together with other green additives, as a novel safe organic solvent in reversed-phase MLC. Quality-by-design (QbD) approach screened their effect on the separation performance.
View Article and Find Full Text PDFJ Appl Clin Med Phys
December 2024
Department of Radiotherapy, University Medical Center Utrecht, Utrecht, Netherlands.
Background: For the development and validation of dynamic treatment modalities and processes on the MR-linac, independent measurements should be performed that validate dose delivery and linac behavior at a high temporal resolution. To achieve this, a detector with both high temporal and spatial resolution is necessary.
Purpose: This study investigates the suitability of a Delta4 Phantom+ MR (Delta4) detector array for time-resolved dosimetry in the 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!