To evaluate the diagnostic efficacy of CCTA + plain scan for ruptured plaques, with optical coherence tomography (OCT) as the reference, and to provide preliminary analysis of influential factors. Patients who underwent CCTA and OCT were retrospectively enrolled. The diagnostic standards for ruptured plaque on CCTA + plain scan were ulcer or intra-plaque dye penetration on CCTA, and a careful review of images from the plain scans to ensure areas of them were not calcification. The diagnosis of ruptured plaque was made by OCT. Total 65 patients with 71 plaques were included. There were 40 OCT-confirmed ruptured plaques in 38 patients and 31 OCT-confirmed non-ruptured plaques in 27 patients. CCTA + plain scan identified 27 ruptured plaques in 27 patients and 28 non-ruptured plaques in 24 patients. With OCT as the gold standard, the per-patient sensitivity, specificity, positive and negative predictive values, and accuracy of CCTA + plain scan for diagnosing ruptured plaque were 71%, 89%, 90%, 69%, and 78%, and there was good agreement (Kappa = 0.70) between CCTA + plain scan and OCT. Among 13 false negative ruptured plaques, 2 had calcifications close to the rupture, and the cavity depth in the remaining 11 was 0.46 ± 0.17 mm, versus 0.98 ± 0.26 mm in 27 true positive ruptured plaques (P < 0.01). CCTA + plain scan may identify morphological features of ruptured plaques. The cavity depth of the ruptured plaques and calcification at the rupture site seem major factors influencing the diagnostic accuracy for plaque rupture. Future perspective studied are needed to confirm these preliminary findings.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-021-02253-9DOI Listing

Publication Analysis

Top Keywords

ccta + plain scan
20
ruptured plaques
20
ruptured plaque
16
plaques patients
16
ruptured
9
diagnosis ruptured
8
optical coherence
8
coherence tomography
8
plaques
8
non-ruptured plaques
8

Similar Publications

Texture analysis generates image parameters from F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). Although some parameters correlate with tumor biology and clinical attributes, their types and implications can be complex. To overcome this limitation, pseudotime analysis was applied to texture parameters to estimate changes in individual sample characteristics, and the prognostic significance of the estimated pseudotime of primary tumors was evaluated.

View Article and Find Full Text PDF

This study examined scan speed, hatch distance, and scan rotation angle parameters to determine the effects of the powder bed fusion process on the tensile strength of AlSi10Mg material. The Taguchi L9 experimental design was applied to evaluate the effects of the parameters systematically. The experimental results revealed the importance of the parameters affecting the tensile strength of the AlSi10Mg material.

View Article and Find Full Text PDF

Objective: To investigate differences in arterial involvement patterns on F-FDG PET-CT between predominant cranial and isolated extracranial phenotypes of giant cell arteritis (GCA).

Methods: A retrospective review of F-FDG PET-CT findings was conducted on 140 patients with confirmed GCA. The patients were divided into two groups: the cranial group, which presented craniofacial ischemic symptoms either at diagnosis or during follow-up, and the isolated extracranial group which never exhibited such manifestations.

View Article and Find Full Text PDF

Complete arch oral implant treatment using photogrammetry was studied in 77 patients with 111 arches focusing on digitization of clinical records and optimization of the provisional. The aim of the study was to test the hypothesis that patient satisfaction with the provisional prosthesis during the first 4 months of care determined workflow efficiency and success. Digitization of 8 clinical records was done including centric relation, vertical dimension, esthetics, occlusion, inter-arch space, abutment selection, abutment capture, and soft tissue scan.

View Article and Find Full Text PDF

Systemic hydroa vacciniforme lymphoproliferative disorder in a patient with chronic active EBV infection.

BMJ Case Rep

December 2024

Dermatology, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA

Hydroa vacciniforme lymphoproliferative disorders (HVLPD) fall within the clinical spectrum of chronic active epstein barr virus (EBV) disease (CAEBVD), ranging from localised and/or indolent forms (classic HVLPD) to systemic disease with fever, hepatosplenomegaly and lymphadenopathy (systemic HVLPD). A preadolescent male with 47XYY, multicystic dysplastic kidney, autism spectrum disorder and Attention-deficit/hyperactivity disorder (ADHD) presented with photodistributed non-pruritic, non-painful necrotic papulovesicles accompanied by non-febrile intermittent fatigue and lymphadenopathy. The patient had a history of EBV pneumonia in infancy confirmed by CT scan and was later diagnosed with CAEBV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!