Diagnosis of symptomatic valve malfunction in hydrocephalic patients treated with VP-Shunt (VPS) might be difficult. Clinical symptoms such as headache or nausea are nonspecific, hence cerebrospinal fluid (CSF) over- or underdrainage can only be suspected but not proven. Knowledge concerning valve malfunction is still limited. We aim to provide data on the flow characteristics of explanted shunt valves in patients with suspected valve malfunction. An in vitro shunt laboratory setup was used to analyze the explanted valves under conditions similar to those in an implanted VPS. The differential pressure (DP) of the valve was adjusted stepwise to 20, 10, 6, and 4 cmHO. The flow rate of the explanted and the regular flow rate of an identical reference valve were evaluated at the respective DPs. Twelve valves of different types (Codman CertasPlus valve n = 3, Miethke Shuntassistant valve n = 4, Codman Hakim programmable valve n = 3, DP component of Miethke proGAV 2.0 valve n = 2) from eight hydrocephalic patients (four male), in whom valve malfunction was assumed between 2016 and 2017, were replaced with a new valve. Four patients suffered from idiopathic normal pressure (iNPH), three patients from malresorptive and one patient from obstructive hydrocephalus. Post-hoc analysis revealed a significant difference (p < 0.001) of the flow rate between each explanted valve and their corresponding reference valve, at each DP. In all patients, significant alterations of flow rates were demonstrated, verifying a valve malfunction, which could not be objectified by the diagnostic tools used in the clinical routine. In cases with obscure clinical VPS insufficiency, valve deficiency should be considered.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8827297 | PMC |
http://dx.doi.org/10.1007/s10143-021-01564-8 | DOI Listing |
Clin Appl Thromb Hemost
January 2025
Cardiovascular Research Institute, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.
View Article and Find Full Text PDFA A Pract
December 2024
From the Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences (AIIMS), Rishikesh, Uttarakhand, India.
The circle breathing system enables rebreathing using a carbon dioxide absorbent. This case report presents a rare incident of ventilation failure in a 30-year-old male patient due to a broken unidirectional valve in a soda lime canister. Despite the anesthesia machine passing automated checks, a mechanical blockage from caked soda lime in the inner inspiratory chamber led to insufficient tidal volume delivery.
View Article and Find Full Text PDFCaspian J Intern Med
October 2024
Department of Dermatopathology, Raazi Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Background: Mastocytosis is a systemic disease involving the clonal expansion of mast cells in multiple organs. Given that immune system overreaction and excessive histamine release are among the most prominent events in mastocytosis, the incidence of complications caused by immune reactions is expected to increase across various organs. While systemic manifestations of mastocytosis have been reported frequently, cardiac complications are less often discussed.
View Article and Find Full Text PDFChildren (Basel)
October 2024
Neurosurgical Department, General Hospital of Athens 'Gennimatas', 10676 Athens, Greece.
Cureus
October 2024
Neurosurgery, Kawasaki Municipal Tama Hospital, Kawasaki, JPN.
We report a rare case of shunt valve failure due to obstruction during ventriculoperitoneal (VP) shunt surgery for hydrocephalus after subarachnoid hemorrhage due to aneurysm rupture. The hydrocephalus shunt surgery was started normally, and there was no bending or twisting of the valve, nor blood contamination. However, after irrigation of the shunt valve, the shunt valve obstructed and malfunctioned before catheter connection and insertion into the subcutaneous space.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!