Purpose: To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion.
Materials And Methods: A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points.
Results: In Group 1 for vertical load , maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1.
Conclusion: In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8110741 | PMC |
http://dx.doi.org/10.4047/jap.2021.13.2.79 | DOI Listing |
Materials (Basel)
January 2025
Faculty of Furniture Design and Wood Engineering, Transilvania University of Brasov, B-dul Eroilor, nr. 29, 500036 Brasov, Romania.
The present paper investigates the possibility of replacing the traditional L-type corner joint used in chair construction with a 3D printed connector, manufactured using the Fused Filament Fabrication (FFF) method and black PLA as filament. The connector was designed to assemble the legs with seat rails and stretchers, and it was tested under diagonal tensile and compression loads. Its performance was compared to that of the traditional mortise-and-tenon joint.
View Article and Find Full Text PDFBackground: The lives of adolescents and young people living with HIV (LHIV) are dominated by complex psychological and social stressors. These may be more pronounced among those perinatally infected. This longitudinal mixed-methods study describes the clinical and psychosocial challenges faced by HIV perinatally infected young mothers in Harare, Zimbabwe to inform tailored support.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Key Laboratory of New Technology for Construction of Cities in Mountain Area, School of Civil Engineering, Chongqing University, Chongqing 400000, China.
According to the mechanical characteristics of joints in steel-concrete composite bridge decks under the combined bending and shear, improved joint details with simple structure and convenient construction were studied, including lapped U-bars, lapped headed bars, and lapped hook bars. In order to test the mechanical properties of the three joint details and compare them with the existing lapped/welded linear bars, the tests of five specimens were carried out. The cracking load, ultimate load, failure mode, crack pattern, and reinforcement strain were analyzed.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
The Building Technology Department, Linnæus University, 352 52 Växjö, Sweden.
Timber-concrete composites are established structural elements to combine the advantageous properties of both materials by connecting them. In this work, an innovative flexible adhesive connection in different configurations is investigated. Load-bearing capacity, stiffness, and the failure modes were first experimentally investigated by performing push-out tests.
View Article and Find Full Text PDFThis study compared the effects of a sled push priming session on performance in 20 m sprint times, vertical jump, and perceived recovery, in comparison to a control condition, during competitive microcycles. Sixteen young semi-professional football players completed two conditions: priming (heavy sled pushes and MD-1 training) and control (only MD-1 regular training), in a crossover design. Twenty-metre sprint times and countermovement jump (CMJ) were assessed 24 hours following the completion of the experimental sessions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!