A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Weight-Bearing Restrictions With Distal Radius Wrist-Spanning Dorsal Bridge Plates. | LitMetric

Weight-Bearing Restrictions With Distal Radius Wrist-Spanning Dorsal Bridge Plates.

J Hand Surg Am

Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI; University Orthopedics Incorporated, Providence, RI.

Published: February 2022

Purpose: The fixation of comminuted distal radius fractures using wrist-spanning dorsal bridge plates has been shown to have good postoperative results. We hypothesized that using a stiffer bridge plate construct results in less fracture deformation with loads required for immediate crutch weight bearing.

Methods: We created a comminuted, extra-articular fracture in 7 cadaveric radii, which were fixed using dorsal bridge plates. The specimens were positioned to simulate crutch/walker weight bearing and axially loaded to failure. The axial load and mode of failure were measured using 2- and 5-mm osteotomy deformations as cutoffs. Bearing 50% and 22% of the body weight was representative of the force transmitted through crutch and walker weight bearing, respectively.

Results: The load to failure at 2-mm deformation was greater than 22% body weight for 2 of 7 specimens and greater than 50% for 1 of 7 specimens. The load to failure at 5-mm deformation was greater than 22% body weight for 6 of 7 specimens and greater than 50% for 4 of 7 specimens. The mean load to failure at 2-mm gap deformation was significantly lower than 50% body weight (110.4 N vs 339.2 N). The mean load to failure at 5-mm deformation was significantly greater than 22% body weight (351.8 N vs 149.2 N). All constructs ultimately failed through plate bending.

Conclusions: All constructs failed by plate bending at forces not significantly greater than the 50% body weight force required for full crutch weight bearing. The bridge plates supported forces significantly greater than the 22% body weight required for walker weight bearing 6 of 7 times when 5 mm of deformation was used as the failure cutoff.

Clinical Relevance: Elderly, walker-dependent patients may be able to use their walker as tolerated immediately after dorsal bridge plate fixation for extra-articular fractures. However, patients should not be allowed to bear full weight using crutches immediately after bridge plating.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2021.04.008DOI Listing

Publication Analysis

Top Keywords

body weight
28
22% body
20
dorsal bridge
16
bridge plates
16
weight bearing
16
load failure
16
greater 22%
16
weight
13
deformation greater
12
greater 50%
12