We propose a novel prompt-gamma (PG) imaging modality for real-time monitoring in proton therapy: PG time imaging (PGTI). By measuring the time-of-flight (TOF) between a beam monitor and a PG detector, our goal is to reconstruct the PG vertex distribution in 3D. In this paper, a dedicated, non-iterative reconstruction strategy is proposed (PGTI reconstruction). Here, it was resolved under a 1D approximation to measure a proton range shift along the beam direction. In order to show the potential of PGTI in the transverse plane, a second method, based on the calculation of the centre of gravity (COG) of the TIARA pixel detectors' counts was also explored. The feasibility of PGTI was evaluated in two different scenarios. Under the assumption of a 100 ps (rms) time resolution (achievable in single proton regime), MC simulations showed that a millimetric proton range shift is detectable at 2with 10incident protons in simplified simulation settings. With the same proton statistics, a potential 2 mm sensitivity (at 2with 10incident protons) to beam displacements in the transverse plane was found using the COG method. This level of precision would allow to act in real-time if the treatment does not conform to the treatment plan. A worst case scenario of a 1 ns (rms) TOF resolution was also considered to demonstrate that a degraded timing information can be compensated by increasing the acquisition statistics: in this case, a 2 mm range shift would be detectable at 2with 10incident protons. By showing the feasibility of a time-based algorithm for the reconstruction of the PG vertex distribution for a simplified anatomy, this work poses a theoretical basis for the future development of a PG imaging detector based on the measurement of particle TOF.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ac03caDOI Listing

Publication Analysis

Top Keywords

range shift
12
2with 10incident
12
10incident protons
12
prompt-gamma imaging
8
proton therapy
8
vertex distribution
8
proton range
8
transverse plane
8
shift detectable
8
detectable 2with
8

Similar Publications

Inorganic-organic hybrid nanoparticles with carbonate-triggered emission-colour-shift.

Dalton Trans

January 2025

Karlsruhe Institute of Technology (KIT), Institute for Inorganic Chemistry, Engesserstrasse 15, 76131 Karlsruhe, Germany.

(Eu[PTC])(Eu[TREN-1,2-HOPO]) inorganic-organic hybrid nanoparticles (IOH-NPs) contain Eu, tris[(1-hydroxy-2-oxo-1,2-dihydropyridine-6-carboxamido)ethyl]amine (TREN-1,2-HOPO) and perylene-3,4,9,10-tetracarboxylate (PTC). The IOH-NPs are prepared in water and exhibit a rod-type shape, with a length of 60 nm and a diameter of 5 nm. Particle size and chemical composition are examined by different methods (SEM, DLS, FT-IR, TG, C/H/N analysis).

View Article and Find Full Text PDF

We report the complex dielectric function = + of MoS/WS and WS/MoS heterostructures and their constituent monolayers MoS and WS for an energy range from 1.5 to 6.0 eV and temperatures from 39 to 300 K.

View Article and Find Full Text PDF

Technology-critical elements (TCEs) refer to the elements that play an important role in many emerging technologies and the production of advanced materials, and these include lanthanides, tungsten and vanadium. Actinides, Tl, and Pb, which also belong to TCEs, are abundantly used in power generation, industrial applications, and modern agricultural practices. The information on the influence of these elements on the aquatic environment and biota is still rather scarce.

View Article and Find Full Text PDF

Aims: To date, bariatric surgery (BS) is the most effective long-term treatment for obesity, but weight regain (WR) is common. The very low-calorie ketogenic diet (VLCKD) is effective for weight loss and may influence gut microbiota (GM) composition, but it has been scarcely evaluated in post-bariatric patients. This study compared the efficacy and safety of a VLCKD in patients with WR post-bariatric surgery (BS+) and in bariatric surgery-naïve patients (BS-).

View Article and Find Full Text PDF

Facultative scavenging can be observed across a large range of carnivorous mammals but is an uncommon behavioural trait in cheetahs (). Very few incidents of cheetahs scavenging have been reported, with no explanation given as to why it may occur. In this paper, we provide three more observations of cheetahs scavenging between 2019 and 2023 in three different protected areas in South Africa and Malawi.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!