Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Ultrasensitive and ultraselective detection of the gene requires emergency development to meet the medical demands and infectious disease control. Herein we report a versatile and scalable method based on electrochemical-chemical-cyclic amplification (EC-CA) and fluorescence detection for ultrasensitive gene sensing. The EC-CA is achieved by an electro-Fenton reaction (EFR). The hydroxyl radicals generated at EFR are trapped by terephthalic acid to form highly fluorescent 2-hydroxyterephthalic acid, which can be sensitively detected by a fluorescence spectrophotometer. The method is the first to be able to amplify the signal and reduce the noise simultaneously by using the conventional analytical methods directly. This described method can be used for reliable Fe quantification in the range from 0.1 nM to 0.08 mM. The calculated limit of detection (LOD) is 0.02 nM. Then, hepatitis B virus (HBV) and p53 gene were detected by this proposed method through introducing the FeO nanoparticles into the gene hybridization system. The LODs for HBV and p53 gene even topped out at 2.6 pM and 1.7 fM, respectively. We demonstrated that the finally recorded signal was triply amplified through the EC cycle, FeO nanoparticles, and sensitive fluorescence detection. At the same time, the background signal arisen from matrix effects and readout noise was effectively suppressed. This method shows it is simple, convenient, and operational through the detection of Fe, HBV, and the p53 gene in blood samples, respectively. We believe our method will make a significant, near-term impact on the development of high-sensitivity methods that are versatile and scalable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.1c01404 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!