A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

When Fluorescent Sensing Meets Electrochemical Amplifying: A Powerful Platform for Gene Detection with High Sensitivity and Specificity. | LitMetric

When Fluorescent Sensing Meets Electrochemical Amplifying: A Powerful Platform for Gene Detection with High Sensitivity and Specificity.

Anal Chem

Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, China.

Published: June 2021

Ultrasensitive and ultraselective detection of the gene requires emergency development to meet the medical demands and infectious disease control. Herein we report a versatile and scalable method based on electrochemical-chemical-cyclic amplification (EC-CA) and fluorescence detection for ultrasensitive gene sensing. The EC-CA is achieved by an electro-Fenton reaction (EFR). The hydroxyl radicals generated at EFR are trapped by terephthalic acid to form highly fluorescent 2-hydroxyterephthalic acid, which can be sensitively detected by a fluorescence spectrophotometer. The method is the first to be able to amplify the signal and reduce the noise simultaneously by using the conventional analytical methods directly. This described method can be used for reliable Fe quantification in the range from 0.1 nM to 0.08 mM. The calculated limit of detection (LOD) is 0.02 nM. Then, hepatitis B virus (HBV) and p53 gene were detected by this proposed method through introducing the FeO nanoparticles into the gene hybridization system. The LODs for HBV and p53 gene even topped out at 2.6 pM and 1.7 fM, respectively. We demonstrated that the finally recorded signal was triply amplified through the EC cycle, FeO nanoparticles, and sensitive fluorescence detection. At the same time, the background signal arisen from matrix effects and readout noise was effectively suppressed. This method shows it is simple, convenient, and operational through the detection of Fe, HBV, and the p53 gene in blood samples, respectively. We believe our method will make a significant, near-term impact on the development of high-sensitivity methods that are versatile and scalable.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.1c01404DOI Listing

Publication Analysis

Top Keywords

hbv p53
12
p53 gene
12
versatile scalable
8
fluorescence detection
8
feo nanoparticles
8
gene
7
detection
6
method
6
fluorescent sensing
4
sensing meets
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!