How to improve automated external defibrillator placement for out-of-hospital cardiac arrests: A case study.

PLoS One

Emergency Department, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland.

Published: November 2021

Introduction: In out-of-hospital cardiac arrests (OHCAs), the use of an automatic external defibrillator (AED) by a bystander remains low, as AEDs may be misplaced with respect to the locations of OHCAs. As the distribution of historical OHCAs is potentially predictive of future OHCA locations, the purpose of this study is to assess AED positioning with regard to past locations of OHCAs, in order to improve the efficiency of public access defibrillation programs.

Methods: This is a retrospective observational study from 2014 to 2018. The locations of historical OHCAs and AEDs were loaded into a geodata processing tool. Median distances between AEDs were collected, as well as the number and rates of OHCAs covered (distance of <100 meters from the nearest AED). Areas with high densities of uncovered OHCAs (hotspots) were identified in order to propose the placement of additional AEDs. Areas over-covered by AEDs (overlays) were also identified in order to propose the relocation of overlapping AEDs.

Results: There were 2,971 OHCA, 79.3% of which occurred at home, and 633 AEDs included in the study. The global coverage rate was 7.5%. OHCAs occurring at home had a coverage rate of 4.5%. Forty hotspots were identified, requiring the same number of additional AEDs. The addition of these would increase the coverage from 7.5% to 17.6%. Regarding AED overlays, 17 AEDs were found to be relocatable without reducing the AED coverage of historical OHCAs.

Discussion: This study confirms that geodata tools can assess AED locations and increase the efficiency of their placement. Historical hotspots and AED overlays should be considered, with the aim of efficiently relocating or adding AEDs. At-home OHCAs should become a priority target for future public access defibrillation programs as they represent the majority of OHCAs but have the lowest AED coverage rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136701PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0250591PLOS

Publication Analysis

Top Keywords

external defibrillator
8
out-of-hospital cardiac
8
cardiac arrests
8
locations ohcas
8
historical ohcas
8
ohcas
6
improve automated
4
automated external
4
defibrillator placement
4
placement out-of-hospital
4

Similar Publications

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

The aim of this study was to assess the frailty status of patients with heart failure undergoing CRT-D and then explore the predictive value of frailty for all-cause mortality and heart failure-related readmissions in these patients. We retrospectively included 374 patients with chronic heart failure who underwent CRT-D treatment at the First Affiliated Hospital of Xinjiang Medical University between June 2020 and June 2024. Based on the Tilburg Debilitation Assessment Scale, 175 patients (46.

View Article and Find Full Text PDF

Can ICD Electrograms Help Ventricular Tachycardia Ablation?: Results From the Multicenter Randomized AIDEG-VTA Trial.

J Am Coll Cardiol

November 2024

Electrophysiology Laboratory and Arrhythmia Unit, Centro Integral de Enfermedades Cardiovasculares, Hospital Monteprincipe, Grupo HM Hospitales, Madrid, Spain. Electronic address:

Background: The results of ablation of sustained monomorphic ventricular tachycardia (SMVT) are suboptimal. For many patients with implantable cardioverter-defibrillators (ICDs), ICD electrograms (ICD-EGs) provide the only available information on SMVT. ICD-EGs have the ability to distinguish morphologically distinct SMVT and can be used for pace mapping.

View Article and Find Full Text PDF

Catheter-related thrombosis (CRT) is a frequent and potentially serious complication associated with the widespread use of intravascular devices such as central venous catheters, including peripherally inserted central catheters and implantable port systems, pacemakers or implantable cardioverter-defibrillators. Although CRT management has been informed by guidelines extrapolated from lower extremity deep vein thrombosis (DVT), unique challenges remain due to the distinct anatomical, pathophysiological, and clinical characteristics of upper extremity DVT. Risk factors for CRT are multifactorial, encompassing patient-related characteristics such as cancer, prior venous thromboembolism, and infection, as well as catheter-specific factors like device type, lumens, and insertion site.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!