Exploring "wear and tear" of joints and "muscle function" assumptions in skeletons with known occupation at death.

Am J Phys Anthropol

Laboratório de Antropologia Biológica e Osteologia Humana (LABOH), Centro em Rede de Investigação em Antropologia (CRIA), Faculdade de Ciências Sociais e Humanas, Universidade NOVA de Lisboa (FCSH/NOVA), Lisbon, Portugal.

Published: July 2021

Objectives: Changes in the joints are believed to result from "wear and tear," a consequence of activity, as entheseal changes (EC) result from muscle use. However, clinical data showed that activity does not necessarily increase the likelihood of degenerative joint changes (DJC) and that exercise results in healthier joints. We tested whether individuals with continuous repetitive biomechanical efforts (Group 1) were more likely to exhibit EC and if occupations known to exert strenuous but discontinued efforts (Group 2) would more likely cause DJC.

Materials And Methods: Eighty-nine males with known occupations from Portuguese identified collections were used: shoemakers and carpenters (Group 1), workers (Group 2), and civil servants, and shop assistants as a control group. Major upper and lower limb joints and entheses sites were used. DJC and EC were tested between occupations - while controlling for age (overall approach) - and within occupation (occupation-specific approach).

Results: The overall approach showed that age - as a covariant - had a significant impact on DJC and EC development (p < 0.05), with occupation being non-significant (p > 0.05) despite the variability in the mean-values of lesions. The occupation-specific approach showed a significant variability of DJC and EC correlations, within and between occupations, with no clear trend of DJC and EC development according to occupation.

Discussion: The results showed that exploring overall patterns might conceal occupation-specific joint and muscle use, emphasizing age as a major contributor of changes; and that the occupation-specific approach highlighted particular aspects associated with occupations, allowing for a more informative assessment of strenuous repetitive or discontinuous activity-related technical gestures and their impact on skeletal biology.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ajpa.24334DOI Listing

Publication Analysis

Top Keywords

"wear tear"
8
efforts group
8
djc development
8
occupation-specific approach
8
djc
5
group
5
occupations
5
exploring "wear
4
joints
4
tear" joints
4

Similar Publications

Metallic nanomaterials show tremendous applications in biomedical devices due to compatible integration into the most of the biological systems as they are nano- structured. Metallic nanomaterials are capable of mimicking all the three major antioxidant enzymes such as catalase (CAT), peroxidase and oxidase, to control the level of reactive oxygen species (ROS) inside the cell as an alternative strategy over conventional one which has biological toxicity and have several adverse effects, if accumulation takes places during the treatment. This anti-oxidant property of metallic nanomaterials demonstrates as a promising candidate for its biomedical application in disease conditions where the excessive level of ROS causes damage to DNA, lipids and protein in several conditions such as diabetes, cancer and neurodegenerative diseases.

View Article and Find Full Text PDF

Conodont elements are the earliest mineralized vertebrate dental tools and the only ones capable of extensive repair. Two models of conodont growth, as well as the presence of a larval stage, have been hypothesized. We analysed normally and pathologically developed elements to test these hypotheses and identified three ontogenetic stages characterized by different anisometric growth and morphology.

View Article and Find Full Text PDF

Silicone Hydrogel and Rigid Gas-Permeable Scleral Lens Tear Exchange.

Eye Contact Lens

March 2018

Southern California College of Optometry (J.R.P., E.C., T.E., B.A.W.), Marshall B. Ketchum University, Fullerton, CA; Private Practice (C.H.), College Station, TX; Department of Ophthalmology (H.M.), University of California, Davis, Sacramento, CA; Private Practice (T.G.), Broomfield, CO; Department of Mathematics, California State University (A.L.N.), Fullerton, CA; and Stein Eye Institute (B.A.W.), David Geffen School of Medicine at UCLA, Los Angeles, CA.

Objectives: To quantify tear elimination rate (ER) underneath silicone hydrogel (Si-Hy) and scleral gas permeable (GP) contact lenses (CLs).

Methods: Subjects successfully using either well-fitting soft Si-Hy CLs or scleral GP CLs were recruited. Most scleral GP CL wearers had irregular corneas (e.

View Article and Find Full Text PDF

Cartilage degeneration are hallmarks of wear, tear, mechanical and inflammatory damage of the joint cartilage. Tissue degradation as well as compromising the integrity and function of the organ, produces different intermediates, directly able to stimulate further inflammatory effect, therefore, amplifying the inflammation response. Biglycan is a soluble component of the extracellular matrix that is released during tissue injury.

View Article and Find Full Text PDF

Contact lens wear is one of the primary risk factors for the development of ocular surface inflammatory events. The purpose of this review is to examine and summarize existing knowledge on the mechanisms of contact lens related ocular surface inflammation and the evidence for the effectiveness of current objective methods to measure ocular surface inflammation. Contact lens wear is postulated to trigger an inflammatory response on the ocular surface due to mechanical, chemical, hypoxic stress, or by the introduction of microbes and their toxins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!