X-ray transmission imaging has been used in a variety of applications for high-resolution measurements based on shape and density. Similarly, X-ray diffraction (XRD) imaging has been used widely for molecular structure-based identification of materials. Combining these X-ray methods has the potential to provide high-resolution material identification, exceeding the capabilities of either modality alone. However, XRD imaging methods have been limited in application by their long measurement times and poor spatial resolution, which has generally precluded combined, rapid measurements of X-ray transmission and diffraction. In this work, we present a novel X-ray fan beam coded aperture transmission and diffraction imaging system, developed using commercially available components, for rapid and accurate non-destructive imaging of industrial and biomedical specimens. The imaging system uses a 160 kV Bremsstrahlung X-ray source while achieving a spatial resolution of ≈ 1 × 1 mm and a spectral accuracy of > 95% with only 15 s exposures per 150 mm fan beam slice. Applications of this technology are reported in geological imaging, pharmaceutical inspection, and medical diagnosis. The performance of the imaging system indicates improved material differentiation relative to transmission imaging alone at scan times suitable for a variety of industrial and biomedical applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8134570 | PMC |
http://dx.doi.org/10.1038/s41598-021-90163-0 | DOI Listing |
Adv Radiat Oncol
February 2025
Department of Advanced Radiation Oncology and Proton Therapy, Inova Schar Cancer Institute, Fairfax, Virginia.
Purpose: This study evaluates the hypothesis that a volumetric skin-sparing planning technique (SSPT) will reduce acute dermatitis in patients treated to the breast or chest wall (CW) with proton pencil-beam scanning (PBS).
Methods And Materials: In January 2022, our center incorporated volumetric-based skin-sparing objectives in addition to skin hot spot evaluation as an SSPT. The SSPT incorporated an objective to limit the volume of a skin evaluation structure (skin-eval) receiving 95% of the prescription dose or more (V95%Rx) to ideally < 50%.
J Clin Densitom
December 2024
Service de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, France; Physiologie et Médecine Expérimentale du Cœur et des Muscles (PhyMedEx), INSERM, CNRS, Université de Montpellier (UM), France.
Purpose: The aim of this study was to investigate the correlations between areal bone mineral density (aBMD) and body composition measured by two dual-energy X-ray absorptiometers (DXA), the DMS Stratos® (STR) and the Hologic Horizon A® (HRZ), and then generate cross-calibration equations between the two scanners.
Methods: Repeat scans were obtained from 251 adults (85 % female), 36 ± 14 years old with mean body mass index (BMI) of 28.7 ± 11.
ACS Omega
December 2024
School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031, Sichuan, China.
Photocatalysts composed of ZnSe nanorods were prepared by using a glancing angle deposition technique facilitated by electron beam evaporation equipment. To enhance the photocatalytic efficiency of ZnSe, a vulcanization process was introduced. The impact of various parameters, including curing temperature, duration, and nanorod length, on the photocatalytic performance was systematically examined.
View Article and Find Full Text PDFJ Appl Clin Med Phys
December 2024
Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.
Background: Immobilization devices are essential for maintaining accurate and repeatable patient positioning in radiotherapy. This study aimed to evaluate the setup errors and dosimetric deviation induced by the deformation of immobilization devices in thoracic cancer radiotherapy using CT-linac.
Materials And Methods: A retrospective analysis was conducted on 40 thoracic cancer patients who underwent radiotherapy, using vacuum cushion (VC) and thermoplastic mask (TM) for immobilization.
Med Phys
December 2024
Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton scattered x-ray photons.
Purpose: The objective of this study is to develop a novel scatter correction method, named e-Grid, for DL-FPD based CBCT imaging.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!