Correction to: Fully-automated synthesis of 177Lu labelled FAPI derivatives on the module modular lab-Eazy.

EJNMMI Radiopharm Chem

Moltek A. S. Gebze Organize Sanayi, 41400, Gebze, Kocaeli, Turkey.

Published: May 2021

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8134592PMC
http://dx.doi.org/10.1186/s41181-021-00134-zDOI Listing

Publication Analysis

Top Keywords

correction fully-automated
4
fully-automated synthesis
4
synthesis 177lu
4
177lu labelled
4
labelled fapi
4
fapi derivatives
4
derivatives module
4
module modular
4
modular lab-eazy
4
correction
1

Similar Publications

Background: INTER- and INTRAmuscular fat (IMF) is elevated in high metabolic states and can promote inflammation. While magnetic resonance imaging (MRI) excels in depicting IMF, the lack of reproducible tools prevents the ability to measure change and track intervention success.

Methods: We detail an open-source fully-automated iterative threshold-seeking algorithm (ITSA) for segmenting IMF from T1-weighted MRI of the calf and thigh within three cohorts (CaMos Hamilton (N = 54), AMBERS (N = 280), OAI (N = 105)) selecting adults 45-85 years of age.

View Article and Find Full Text PDF

Solid phase extraction chromatography-based radiochemical isolation of cyclotron-produced Mn from enriched Fe targets.

Nucl Med Biol

December 2024

University of Wisconsin Department of Medical Physics, 1111 Highland Avenue, Madison, WI 53705, United States of America; University of Wisconsin Department of Radiology, 600 Highland Avenue, Madison, WI 53792, United States of America. Electronic address:

We report DGA extraction chromatography isolation of Mn from isotopically enriched Fe. The method has been studied in semi-automated and automated realizations. The former achieves a decay corrected radiochemical yield of 78 ± 1 % (n = 3) and a separation factor of (1.

View Article and Find Full Text PDF

A Versatile Drift-Free Super-Resolution Imaging Method via Oblique Bright-Field Correlation.

Adv Sci (Weinh)

December 2024

Department of Bioengineering, Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, Cancer Center at Illinois, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA.

High-resolution optical microscopy, particularly super-resolution localization microscopy, requires precise real-time drift correction to maintain constant focus at nanoscale precision during the prolonged data acquisition. Existing methods, such as fiducial marker tracking, reflection monitoring, and bright-field image correlation, each provide certain advantages but are limited in their broad applicability. In this work, a versatile and robust drift correction technique is presented for single-molecule localization-based super-resolution microscopy.

View Article and Find Full Text PDF

Background: Manual analysis of histopathological images is often not only time-consuming and painstaking but also prone to error from subjective evaluation criteria and human error. To address these issues, we created a fully automated workflow to enumerate jejunal crypts in a microcolony survival assay to quantify gastrointestinal damage from radiation.

Methods And Materials: After abdominal irradiation of mice, jejuna were obtained and prepared on histopathologic slides, and crypts were counted manually by trained individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!