Introduction: Classification of color deficiency has required substantial time and expense with the static Farnsworth-Munsell and Innova Rabin tests. Therefore, dynamic color tests were developed for the Nintendo 3DS.
Methods: Fifteen color deficient patients and 17 age-matched normals performed Rabin color test in addition to PDI Check dynamic color games resembling Farnsworth-Munsell presentation (version 0.2.8) and 3-color iso-luminance gray (version 0.2.13).
Results: Tests of red, green and blue cone-deficient with the v0.2.8 had sensitivity/specificity/PPV of 92%/86%/92% protanopes, 78%/90%/88% deutanopes and 87%/50%/93% tritanopes. Version 0.2.13 had sens/spec/PPV of 78%/83%/78% red-cone, 100%/85%/80% green cone and 67%/78%/33% blue cone. Corresponding IntraClass Correlation (ICC) utilizing v0.2.8 were red-cone 0.22 (-0.02-0.60), green-cone 0.34 (-0.10-0.67) and blue-cone 0.38 (0.12-0.75). ICC for v0.2.13 was higher with protanope 0.62 (-0.07-0.87), deuteranope 0.64 (-0.09-0.88) and tritanope 0.31 (-0.07-0.70). The PDI Check color game took 65 seconds compared to 197 seconds for Innova Rabin.
Conclusion: The PDI Check color game quickly identifies patients with inherited color deficiencies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8124021 | PMC |
http://dx.doi.org/10.2147/OPTO.S305042 | DOI Listing |
Clin Ophthalmol
December 2024
Alaska Blind Child Discovery, Alaska Children's Eye & Strabismus, Anchorage, AK, 99508, USA.
Background: A new, portable computerized distance vision testing (screen plus remote) system called VisionKeys has been developed by the missions equipment developer EyeMobil so we validated it compared to conventional research testing devices.
Methods: Using a standardized protocol of surround HOTV optotype presentation, the VisionKeys was compared to M&S for patched monocular distance visual acuity. A different VisionKeys function with anaglyph spectacle distance stereopsis was compared to near stereo on Titmus circles with Polaroid goggles and PDI Check on an autostereoscopic screen.
Res Rep Trop Med
November 2024
Jungle School of Medicine Kawthoolei, the Free Burma Rangers, Kawthoolei, Karen State, Burma.
Purpose: The rate of moderate-to-severe hearing loss in Southeast Asia is 5.8%, among the world's most prevalent. However, it is difficult to measure for people whose healthcare access is limited by the ongoing civil war.
View Article and Find Full Text PDFAAPS PharmSciTech
October 2024
Department of Pharmacy, Abdul Wali Khan University Mardan, Mardan, 23200, Pakistan.
Int J Radiat Biol
November 2024
Crop Research Unit, Genetics and Plant Breeding, Mohanpur, India.
J Appl Clin Med Phys
July 2024
Department of Radiation Therapy, Genesis Care/21st Century Oncology, Fort Walton Beach, Florida, USA.
Background: Particle accelerators, manufactured for delivering patient radiation treatment, require numerous and frequent quality assurance measures. One of those is the periodic check for electron energy stability. The American Association of Physicists in Medicine has established requirements for this procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!