Trichromatic Enhanced Dynamic Color Screening on the PDI Check Nintendo 3DS Game.

Clin Optom (Auckl)

Alaska Blind Child Discovery, Alaska Children's EYE & Strabismus, Anchorage, AK, USA.

Published: May 2021

Introduction: Classification of color deficiency has required substantial time and expense with the static Farnsworth-Munsell and Innova Rabin tests. Therefore, dynamic color tests were developed for the Nintendo 3DS.

Methods: Fifteen color deficient patients and 17 age-matched normals performed Rabin color test in addition to PDI Check dynamic color games resembling Farnsworth-Munsell presentation (version 0.2.8) and 3-color iso-luminance gray (version 0.2.13).

Results: Tests of red, green and blue cone-deficient with the v0.2.8 had sensitivity/specificity/PPV of 92%/86%/92% protanopes, 78%/90%/88% deutanopes and 87%/50%/93% tritanopes. Version 0.2.13 had sens/spec/PPV of 78%/83%/78% red-cone, 100%/85%/80% green cone and 67%/78%/33% blue cone. Corresponding IntraClass Correlation (ICC) utilizing v0.2.8 were red-cone 0.22 (-0.02-0.60), green-cone 0.34 (-0.10-0.67) and blue-cone 0.38 (0.12-0.75). ICC for v0.2.13 was higher with protanope 0.62 (-0.07-0.87), deuteranope 0.64 (-0.09-0.88) and tritanope 0.31 (-0.07-0.70). The PDI Check color game took 65 seconds compared to 197 seconds for Innova Rabin.

Conclusion: The PDI Check color game quickly identifies patients with inherited color deficiencies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8124021PMC
http://dx.doi.org/10.2147/OPTO.S305042DOI Listing

Publication Analysis

Top Keywords

pdi check
16
dynamic color
12
color
9
check color
8
color game
8
trichromatic enhanced
4
enhanced dynamic
4
color screening
4
pdi
4
screening pdi
4

Similar Publications

Validation of the Affordable, Portable International Visionkeys System for Visual Acuity and Stereopsis.

Clin Ophthalmol

December 2024

Alaska Blind Child Discovery, Alaska Children's Eye & Strabismus, Anchorage, AK, 99508, USA.

Background: A new, portable computerized distance vision testing (screen plus remote) system called VisionKeys has been developed by the missions equipment developer EyeMobil so we validated it compared to conventional research testing devices.

Methods: Using a standardized protocol of surround HOTV optotype presentation, the VisionKeys was compared to M&S for patched monocular distance visual acuity. A different VisionKeys function with anaglyph spectacle distance stereopsis was compared to near stereo on Titmus circles with Polaroid goggles and PDI Check on an autostereoscopic screen.

View Article and Find Full Text PDF

Purpose: The rate of moderate-to-severe hearing loss in Southeast Asia is 5.8%, among the world's most prevalent. However, it is difficult to measure for people whose healthcare access is limited by the ongoing civil war.

View Article and Find Full Text PDF
Article Synopsis
  • - The study developed a thermosensitive gel using nanostructured lipid carriers (NLCs) loaded with paroxetine for nasal delivery to improve depression treatment, employing a microemulsion technique for preparation.
  • - The optimized NLCs had a high entrapment efficiency of around 90%, and showed favorable characteristics, such as a particle size of 155 nm and a gelling temperature suitable for nasal use (31.5°C).
  • - In vivo tests indicated that the paroxetine-loaded NLC gel was more effective in treating depression than the standard NLCs, enhancing brain tissue architecture and reducing inflammatory markers, demonstrating potential for better management of depression through nasal administration.
View Article and Find Full Text PDF
Article Synopsis
  • In India and Bangladesh, lentil crops face serious issues due to foliar blight, prompting researchers to create a mutant population to find a resistant variety, specifically targeting the lack of resistance in existing germplasm.
  • The study produced a gamma-irradiated mutant population, screening nearly 130,000 M2 plants, which led to the identification of a resistant strain called MM216, characterized by a very low disease index compared to standard varieties.
  • The resistant mutant MM216 demonstrated no negative impact on yield despite a slight delay in flowering, indicating its potential for integration into lentil breeding programs worldwide.
View Article and Find Full Text PDF

A slope method for the determination of electron energy for quality assurance.

J Appl Clin Med Phys

July 2024

Department of Radiation Therapy, Genesis Care/21st Century Oncology, Fort Walton Beach, Florida, USA.

Background: Particle accelerators, manufactured for delivering patient radiation treatment, require numerous and frequent quality assurance measures. One of those is the periodic check for electron energy stability. The American Association of Physicists in Medicine has established requirements for this procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!